Oscillator improvements
87
Hint
If you select SINE WAVE 2CH, the L channel sine
wave will be sent to the odd-numbered channel(s)
(or the STEREO L channel) selected by the
ASSIGN (4) parameter described below, and the
R channel sine wave will be sent to the even-num-
bered channel(s) (or the STEREO R channel).
If you select any other, the same signal will be out-
put to all channels selected by the ASSIGN (4)
parameter.
3 PARAMETERS
Here you can set the parameters of the sine wave or
noise. The display in this section will differ depend-
ing on the choice of OSC MODE (2).
If you select SINE WAVE 1CH
A fixed-level sine wave will be sent to the specified
bus(es).
Level meter.................Indicates the output level of
the sine wave.
LEVEL knob
...............Adjusts the output level of
the sine wave in a range of
–96 dB to 0 dB. The current
value is shown in the numer-
ical box below the knob.
FREQ knob
.................Adjusts the frequency of the
sine wave in a range of
20 Hz–20 kHz. The current
value is shown in the numer-
ical box below the knob.
10 kHz / 1 kHz/ 100 Hz
.These buttons set the fre-
quency of the sine wave to
preset values.
If you select SINE WAVE 2CH
The level and frequency of the sine waves can be set
independently for the L channel and R channel. The
content of the parameters are the same as for SINE
WAVE 1CH.
The two sine waves are generated completely inde-
pendently. Even if you set both sine waves to the
same frequency, they will not be in phase. If you
want the phase to match, use SINE WAVE 1CH.
If you select PINK NOISE
Fixed-level pink noise will be sent to the specified
bus(es).
Level meter .................Indicates the output level of
the noise.
LEVEL knob ...............Adjusts the output level of
the noise in a range of
–96 dB to 0 dB. The current
value is shown in the
numerical box below the
knob.
HPF knob / LPF knob
..These knobs continuously
adjust the frequency of the
high pass filter and low pass
filter that process the noise,
in a range of 20 Hz–20 kHz.
The current frequency is
shown in the numerical box
below each knob. You can
also use the ON/OFF but-
tons located below each
numerical box to switch the
high pass filter and low pass
filter on/off.
3
LEVEL knob FREQ knob
Level meter
10kHz / 1kHz /
100Hz
LEVEL knob
FREQ knob
Level meter
10kHz / 1kHz /
100Hz
LEVEL knob HPF knob
LPF knobLevel meter