Using GPI (General Purpose Interface)
41
7. As necessary, use the PARAMETER field located at
the right to specify the parameters, and click the
OK button.
The popup window will close.
8. In the same way, make other GPI IN settings as
desired.
Hint
By displaying GPI IN CONSOLE / GPI IN ENGINE
in the lower part of the screen, you can check the
function that is assigned to each port (p.10).
9. Operate the external device / external switch to
send a control signal to the PM1D system.
The function that is assigned to that GPI IN port will
be executed on the PM1D system.
Hint
Of the functions that can be assigned to GPI IN, Tap
Te mpo is explained in detail on page 51, so you may
refer to that section as well.
Using GPI OUT
Here’s how you can remotely control an external device by sending control signals from GPI OUT when a specific opera-
tion is performed on the PM1D system.
1. Connect your GPI compatible external device to
the GPI connector of the engine or console.
If you are using the PM1D system in Mirror
mode, GPI OUT output always operates in tan-
dem for engines A and B.
If you are using the PM1D system in Dual Con-
sole mode (p.11), only the GPI connector of
the currently-operated console can be used. It is
not possible to modify the settings for the GPI
connector of the other unit, or to receive control
signals from the GPI connector of the other unit.
Furthermore, settings for the GPI connector of
the engine can be made only from console 1.
2. Access the MIDI/GPI/TC function GPI screen.
3. Scroll the GPI OUT list to display the OUTPUT
port that you want to set.
4. According to the character of the signal that your
external device is able to receive, set the POLARITY
field to either Low (grounded when active) or High
(open when active).
5. At the left of the ASSIGNED TRIGGER field, click
the DIRECT ASSIGN button to open the GPI
OUT SETUP popup window.
6. Scroll the list shown at the left side, click the trigger
that you want to assign, and click the OK button.
The popup window will close.
7. In the same way, make other GPI OUT settings as
desired.
Hint
You can use the TEST button in the GPI screen to
test-transmit control signals from each GPI OUT
according to the POLARITY and TRIGGER/TOG-
GLE/TALLY settings. This is a convenient way to ver-
ify that the external device will operate as you expect.
8. Execute the operation that is assigned to GPI OUT.
A control signal will be transmitted from the corre-
sponding GPI OUT port.
Hint
If you want to use GPI OUT as a USER DEFINE des-
tination, make settings in the USER DEFINE screen
(p.52). If you want to use GPI OUT as a destina-
tion from GPI IN, make settings in GPI IN (p.36).
Details on using this as a destination of Fader Start
are given on page 42.