Troubleshooting
Symptom Advice
Cannot turn on the
SREV1.
Make sure that the power cord is connected properly to a suitable AC wall outlet
and the SREV1. See Connecting the Power Cord on page 26 for more informa-
tion.
Make sure that the SREV1 POWER switch is set to ON. See Turning On & Off the
SREV1 on page 26 for more information.
If you still cannot turn on the SREV1, contact your Yamaha dealer.
The POWER indicator
lights up when the SREV1
is turned on, but the
INPUT and OUTPUT
indicators ash
alternately.
Contact your Yamaha dealer.
Cannot turn on the
RC-SREV1.
Make sure that the remote cable is connected between the SREV1 and RC-SREV1
properly. See Connecting the RC-SREV1 Remote Controller on page 22.
Make sure that the RC-SREV1 POWER switch is in the ON position. See Turning
On & Off the RC-SREV1 on page 26 for more information.
The FS LOCK indicators
ash alternately.
The SREV1 is locked but not synchronized to the external wordclock source. See
Selecting the Wordclock Source on page 75 for more information.
The FS LOCK indicators
ash together.
The SREV1 is neither locked nor synchronized to the external wordclock source.
See Selecting the Wordclock Source on page 75 for more information.
The FS status section of
the RC-SREV1 display
shows UNLOCK.
The SREV1 is neither locked nor synchronized to the external wordclock source.
See Selecting the Wordclock Source on page 75 for more information.
Connected an input
signal but theres no
output.
If youre using slot inputs, make sure the I/O cards are installed properly and
secured using the thumbscrews. See Installing I/O Cards on page 84.
Make sure the input is assigned to the proper channel. See Assigning Inputs on
page 35 for more information.
Use the level meters to help trace the signal. See Metering on page 37 for
more information.
Check the channels input and output level settings. See Setting Input & Output
Levels on page 36 for more information.
Is the Bypass mode is set to REV-MUTE, the reverb balance set to 100%, and the
reverb level set to ?
Are you connected to the correct outputs? See Output Assignments on page 9
for more information.
Cant hear any reverb.
Is the SREV1 bypassed. See Bypassing the SREV1 on page 40 for more informa-
tion.
Make sure that the Reverb Balance parameter is not set to 0%. See Main 2
Parameters on page 54 and Fine Reverb Parameters on page 56 for more
information.
Make sure that the Reverb Level parameter is not set to 0 dB. See Fine Reverb
Parameters on page 56 for more information.
Recalled a program but
only its title is displayed,
no program number.
Probably because the program was recalled from a drive. Program numbers
(P01P12) are displayed only when programs are recalled from the Quick memo-
ries. See RC-SREV1 Display on page 18 for more information.