Yamaha MTX3 Manual Page 198

  • Download
  • Add to my manuals
  • Print
  • Page
    / 201
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 197
Alert list Appendix
MTX Editor User’s Manual
198
Amp problems
100
The power supply was shut
down because d.c. was
detected on a speaker output.
It is likely that the device has malfunctioned;
immediately stop using the device and contact
your Yamaha dealer.
Fault Continuing
101
The power supply was shut
down because its temperature
exceeded the allowed limit.
Turn the power off, let the power supply cool
down, then turn the power on again.
Continuous high-power output will cause high
temperatures, so please lower the output
level. If the temperature is still high, check
whether dirt or a foreign object could have
clogged the cooling fan, and clean the fan if
necessary.
Fault Continuing
103
Protection has been activated,
and the power supply was shut
down.
Continuous high-power output may have
activated protection; lower the output level.
For details on the reason that protection was
activated, refer to the owners manual.
Error Continuing
104
Protection has been activated,
and muted.[ch*]
Error Continuing
105
A short circuit was detected in
the speaker output
connector[ch*], so the output
signal has been muted.
It may be that the speaker output connector’s
“+” and “–” are shorted, or that the connected
speaker has malfunctioned.
Fault Single
106
The temperature of the amp
section (heat sink) has
changed, and the speaker
output is now ****.
Continuous high-power output will cause high
temperatures, so please lower the input level
or attenuator. If the temperature is still high,
check whether dirt or a foreign object could
have clogged the cooling fan’s air intake, and
clean it if necessary.
Warning Single
Device information
200
The power to the device has
been turned on.
Information Single
201
The power to the device has
been turned off.
Information Single
202
The firmware update has been
completed.
Information Single
203
Initialization has been
executed.
Information Single
204
Panel lock has been disabled.
Information Single
205
The IP address has been
established.
Information Single
206
The network IP address has
been allocated from the DHCP
server.
Information Single
207
The network IP address has
been released by the DHCP
server.
Information Single
208
An EMG (Emergency) signal
was received, and the device
switched to EMG mode.
Information Continuing
Number Content Action Type
Single/
Continuing
Page view 197
1 2 ... 193 194 195 196 197 198 199 200 201