“Security Settings” dialog box Chapter 7. Dialog boxes
MTX Editor User’s Manual
172
Calibration procedure
1. Connect your external device to the MTX’s [GPI] connector.
2. Select the check box of the channel numbers for which you want to
perform calibration.
If you want to select all channels, select the [All Ports] check box.
3. To specify the detection range, increase the input from the external
device to the maximum and click the [Max] button; then decrease the
input to the minimum and click the [Min] button.
This lets you specify the optimal detection range as appropriate for voltage drop
caused by wiring or due to the specifications of your devices.
The threshold for on/off switching will be the center value between the maximum and
minimum input voltage values (the sum of the maximum value and minimum value,
divided by 2). To prevent malfunctions, you should allow plenty of range for
detection.
If the voltage has dropped because of cable length or noise, adjust the maximum
and minimum input voltage values. Since voltage may become unstable, configure
and set up your external circuit to ensure that there is ample distance between the
maximum and minimum values.
“Security Settings” dialog box
An MTX system lets you specify two types of user account: Administrator and Guest.
You can use this dialog box to specify an administrator PIN code for the project file.
If you log on as administrator to a project file for which a PIN code has been specified, all operations
can be performed; if you log on as guest, the following operations cannot be performed.
Synchronization (going online)
However, you will be able to use the Go Online – From devices” dialog box to obtain
the configuration and parameters of the MTX system.
Saving by overwriting a project file
Editing in the “Project Information” dialog box
Viewing the “Security Settings” dialog box
Updating the firmware and setting the IP address in the “Device Information”
dialog box
Deleting the log in the “Get Log” dialog box
Even if you have logged on as a guest user, you are free to edit the project file.
However since you cannot select the online state, the system that is already set up will
not be modified. Also, the original file will not be modified because you cannot save
by overwriting the project file.