List of settings in “Settings” dialog boxes Appendix
MTX Editor User’s Manual
192
Connection examples using the [GPI OUT] connector
About [OUTPUT TYPE]
[OUTPUT TYPE] allows the following settings.
• Closed
• Open
• Pulse
• Pulse Inv.
Closed
When the selected [FUNCTION] state occurs, the contact will be closed.
In the case of a parameter for which [Threshold] is specified, the contact will be
closed when the threshold value is exceeded.
Open
When the selected [FUNCTION] state occurs, the contact will be opened.
In the case of a parameter for which [Threshold] is specified, the contact will be
opened when the threshold value is exceeded.
If the [FUNCTION] is [Alert], this cannot be selected.
Pulse
If the [Direction] is [Upward], the contact will change from open to closed for
approximately 250 ms when the selected [FUNCTION] state occurs. In the case of a
parameter for which [Threshold] is specified, the contact will change from open to
closed for approximately 250 ms when the threshold value is exceeded.
If the [Direction] is [Downward], the contact will change from open to closed for
approximately 250 ms when the selected [FUNCTION] state is cleared. In the case
of a parameter for which [Threshold] is specified, the contact will change from open
to closed for approximately 250 ms when the value falls below the threshold.
If the [FUNCTION] is [SD Song Play] and [Alert], this cannot be selected.
Pulse Inv.
If the [Direction] is [Upward], the contact will change from closed to open for
approximately 250 ms when the selected [FUNCTION] state occurs. In the case of a
parameter for which [Threshold] is specified, the contact will change from closed to
open for approximately 250 ms when the threshold value is exceeded.
If the [Direction] is [Downward], the contact will change from closed to open for
approximately 250 ms when the selected [FUNCTION] state is cleared. In the case
of a parameter for which [Threshold] is specified, the contact will change from
closed to open for approximately 250 ms when the value falls below the threshold.
If the [FUNCTION] is [SD Song Play] and [Alert], this cannot be selected.
OUT
+V
+5VDC
CPU
10
MTX3
Maximum 75 mA
NOTE
NOTE
NOTE