Yamaha YXR660FAS Service Manual Page 401

  • Download
  • Add to my manuals
  • Print
  • Page
    / 421
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 400
9 - 49
+
ELEC
COOLING SYSTEM
GOOD
CONDITION
6. Thermo switch 3
Remove the thermo switch 3 from the radi-
ator.
Connect the pocket tester ( × 1) to the
thermo switch 3 1.
Immerse the thermo switch 3 in coolant 2.
Check the thermo switch 3 for continuity.
While heating the coolant use a thermom-
eter 3 to record the temperatures.
È
The thermo switch 3 circuit is closed.
É
The thermo switch 3 circuit is open.
Test step Coolant temperature Continuity
1
Less than 75 ± 3 °C
(167 ± 5.4 °F)
No
2
More than 75 ± 3 °C
(167 ± 5.4 °F)
Yes
3
More than 68 °C
(154.4 °F)
Yes
4
Less than 68 °C
(154.4 °F)
No
Test steps 1 & 2: Heating phase
Test steps 3 & 4: Cooling phase
WARNING
Handle the thermo switch 3 with special
care.
Never subject it to a strong shock or allow
it to be dropped. Should it be dropped, it
must be replaced.
T
R
.
.
Thermo switch 3
28 Nm (2.8 m · kg, 20 ft · lb)
*
*
BAD CONDITION
Replace the thermo switch 3.
Page view 400
1 2 ... 396 397 398 399 400 401 402 403 404 405 406 ... 420 421

Comments to this Manuals

No comments