Troubleshooting
ADDITIONAL
INFORMATION
English
During AUTO SETUP
After AUTO SETUP
If the “ERROR” or “WARNING” screens appears, check the cause of the problem, then run “AUTO SETUP” again.
If warning message “W-2” or “W-3” appears, the adjustments are made, however the adjustment may not be optimal.
Depending on the speakers, warning message “W-1” may appears even if the speaker connections are correct.
If error message “E-10” occurs repeatedly, contact a qualified Yamaha service center.
Error message Cause Remedy
See
page
E-1:NO FRONT SP Front L/R channel signals are not detected. Check the front L/R speaker connections. 16
E-2:NO SUR.SP A surround channel signal is not detected. Check the surround speaker connections. 16
E-3:NO PRNS SP A presence channel signal is not detected. Check the presence speaker connections. 16
E-4:SBR.SBL Only right surround back channel signal is
detected.
Connect the surround back speaker to the
SURROUND BACK (SINGLE) speaker
terminal if you only have one surround
back speaker.
16
E-5:NOISY Background noise is too loud. Try running “AUTO SETUP” in a quiet
environment.
Turn off noisy electric equipment like air
conditioners or move them away from the
optimizer microphone.
E-6:CHECK SUR. Surround back speakers are connected,
though surround L/R speakers are not.
Connect surround speakers when you use
surround back speakers.
17
E-7:NO MIC The optimizer microphone was unplugged
during the “AUTO SETUP” procedure.
Connect the supplied optimizer microphone
to the OPTIMIZER MIC jack on the front
panel.
37
E-8:NO SIGNAL The optimizer microphone does not detect
test tones.
Check the microphone setting. 37
Check the speaker connections and
placement.
16
E-9:USER CANCEL The “AUTO SETUP” procedure was
cancelled due to user activity.
Run “AUTO SETUP” again. 37
E-10:INTERNAL ERROR An internal error occurred. Run “AUTO SETUP” again. 37
Warning message Cause Remedy
See
page
W-1:OUT OF PHASE Speaker polarity is not correct. This
message may appear depending on the
speakers even when the speakers are
connected correctly.
Check the speaker connections for proper
polarity (+ or –).
16
W-2:OVER 24m (80ft) The distance between the speaker and the
listening position is over 24 m (80 ft).
Bring the speaker closer to the listening
position.
W-3:LEVEL ERROR The difference of volume level among
speakers is excessive.
Readjust the speaker installation so that all
speakers are set in locations with similar
conditions.
Check the speaker connections. 16
Use speakers of similar quality.
Adjust the output volume of the subwoofer. 37