Chapter 6 Component Guide
DME Designer Owner’s Manual
486
MY16-CII
Right-click the block and select [Open MY-Card Editor] from the context menu to display the editor for it.
* Select “Disable” if you intend to make settings via the CobraNet network using the CobraNet Manager, for example. In such
cases selecting “Enable” may result in incorrect settings.
Section Name/Parameter Range Function
1 Setting from this Window Disable/Enable When “Disable” is selected settings
made via the CobraNet network take
priority. When “Enable” is selected
settings made from the DME Designer
take priority.*
2 High Sampling
Mode
Input Format Double Channel
Single
Selects the format for 88.2/96 kHz
sampling rates.
Linked to Output Format.
Double FS ON/OFF When turned ON the speed of the MY
card word clock output is doubled. Only
available when the card is set as the
word clock master.
Output Format Double Channel
Single
Selects the format for 88.2/96 kHz
sampling rates.
Linked to Input Format.
3 Bundle
Number
Input 0 ~ 65279 Specifies the input bundle number.
Output 0 ~ 65279 Specifies the output bundle number.
4 Serial
Channel
Rx OFF, 1 ~ 15 Specifies the serial receive channel.
Tx OFF, 1 ~ 5 Specifies the serial transmit channel.
5 Properties Bit Length Bit Off
16bit
20bit
24bit
Specifies the output bit rate.
Output is muted when “Bit Off” is
selected.
6 Latency 5.33ms
2.67ms
1.33ms
Specifies the latency.
7 Advanced - Opens the “Advanced Settings”
Window. Refer to “Advanced Settings”
Window on page 481 for details.
NOTE
Refer to the “MY16-CII Owner's Manual” or “CobraNet Manager Lite for YAMAHA Owner's Manual” for mote information on
CobraNet.