Chapter 6 Component Guide
DME Designer Owner’s Manual
407
■ Filter Type
Various types of curves are available for changing the level. Click the [Type] button and select the
type from the menu.
• PEQ
This is a general parametric equalizer.
•L. SHELF (Low Shelving)
There is no sound attenuation at low frequencies. The sound is attenuated at a constant rate
from the cutoff frequency towards the higher frequencies. The attenuation rate per octave can
be set to [6 dB/Oct] or [12 dB/Oct].
• H.SHELF (High Shelving)
There is no sound attenuation at high frequencies. The sound is attenuated at a constant rate
from the cutoff frequency towards the lower frequencies. The attenuation rate per octave can
be set to [6 dB/Oct] or [12 dB/Oct].
• HPF
This is a high-pass filter (Q=0.7). Attenuates the low frequencies with a gentle curve (12 dB/
Oct).
• LPF
This is a low-pass filter (Q=0.7). Attenuates the high frequencies with a gentle curve (12 dB/
Oct).
Section Parameter Setting Range Function
9 Equalizer PEQ ON ON/OFF Turns the PEQ ON
) Output Level -∞ to ±0 dB Sets the output signal level.
! On ON/OFF Turns output ON.