Yamaha V3 Owner's Manual Page 476

  • Download
  • Add to my manuals
  • Print
  • Page
    / 510
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 475
Chapter 6 Component Guide
DME Designer Owner’s Manual
476
The following diagram shows an example in which three DME64N units are cascaded. Signal
transmission and reception between cascade connected DME64N units is bidirectional. Using BUS 1,
the signal from component 1 of DME64N #1 is distributed to DME64N #2 and DME64N #3. Using
BUS 32, the signals from component 4 of DME64N #2 and component 6 of DME64N #3 are summed
and returned to component 2 of DME64N #1.
NOTE
Be careful to avoid loop connections both when connecting via physical cables and in the Designer window.
1
1
2
DME Designer
4
3
3
4
6
2
5
DME Designer
6
5
DME Designer
DME64N #1
DME64N #1
DME64N #2
DME64N #3
CASCADE bus
SummingParallel
CASCADE OUTCASCADE IN
1
32
1
32
DME64N #2
CASCADE OUTCASCADE IN
1
32
1
32
DME64N #3
CASCADE OUTCASCADE IN
1
32
1
32
Physical connection Signal flow between components
IN
BUS 1
BUS 32
OUT
IN
OUT
IN
OUT