205
——
Internal time
clock error
—013
A problem has occurred
with the internal clock, and
it has been initialized
(January 1, 2000, 0:00)
If this occurs each time you turn
on the power, it is possible that
the internal backup battery has
run down or that the device has
malfunctioned. Contact your
Yamaha dealer.
If this occurs only once, an
abnormality was detected with
the clock setting and it was
initialized; use Amp Editor to set
the time.
Fault Continual

Scene recall
error
Scene recall err
The scene could not be
recalled.
It is likely that the device has
malfunctioned; immediately stop
using the device and contact
your Yamaha dealer.
Error Single

Duplicate IP
address
Duplicate IP adr 040
There is an IP address
conflict on the network.
Change the IP addresses so that
there are no duplicates.
Error Continual
——
IP address
setting error
—041
IP address was not set
within 60 seconds of
startup.
Please check rear panel DIP
switch 6 (IP Setting). If DIP
switch 6 is set to “PC,” use Amp
Editor or DHCP server to specify
the device IP address.
Warning Continual
——
Too many
devices on the
network
—043
Too many devices are
connected to the network.
Reduce the number of devices
connected to the network.
Error Single
 Network busy Network busy
Due to heavy network
traffic, communication is
taking time.
Check the devices that are
connected to the network. If an
excessive number of devices are
connected, try reducing the
number of devices. Also make
sure that you are not connected
to the same network as an audio
network.
Information
Continual
——
The UNIT ID is
set to “00”
050 The UNIT ID is set to “00.
Set the UNIT ID to something
other than “00.
Error Continual
——
Duplicate UNIT
ID error
—051
Devices with identical
UNIT IDs were found
connected within the same
network.
Change the UNIT ID so that there
are no duplicates.
Error Continual
Amp
communication
error
Amp comm
error
A problem has occurred in
the transmission at [DATA
PORT] connector (0–31).
Make sure that each of the
connected amplifiers has a
unique ID.
Alternatively, a cable may be
shortcircuited or noise may be
affecting the connection.
Error Single
Word clock
unlocked
WCLK unlocked 021
The word clock master has
become unlocked.
Make sure that the word clock
signal is being input correctly.
This will also appear when you
switch the word clock.
Error Continual
——
YDIF sync error
(Single)
—022
The digital signal being
input to the [YDIF IN]
connector is not
synchronized to the word
clock of this device.
Make sure that YDIF cables are
properly connected.
Use cables that meet the
required specifications.
Error Single
——
YDIF sync error
(Continual)
—023
The digital signal being
input to the [YDIF IN]
connector is not
continuously synchronized
to the word clock of this
device.
Error Continual
——
YDIF input
connection error
—030
There is a problem with the
connection of the [YDIF
IN] connector.
Error Continual
——
Slot sync error
(Single)
SlotSyncErr
Sngl
The digital signal being
input to the slot is not
synchronized to the word
clock of this device
Either input a signal that is
synchronized, or specify the slot
as the word clock master.
Warning Single
——
Slot sync error
(Continual)
SlotSyncErr
Cntn
The digital signal being
in
put to the slot is not
continuously synchronized
to the word clock of this
device.
Information
Continual
TXn
ACD1
XMV
Message
(shown in
Amp Editor)
Message
(shown on
TXn/ACD1)
Alert number
(shown on
XMV)
Content Response Initial type
Single/
Continual
Page view 204

Comments to this Manuals

No comments