INSP
REG
3-30
4.Check:
electrolyte level
The electrolyte level should be between the
minimum level mark and the maximum
level mark .
Below the minimum level mark Add distilled
water to the proper level.
Add only distilled water. Tap water contains
minerals which are harmful to the battery.
5.Check:
specific gravity
Less than 1.280 Recharge the battery.
Specific gravity
1.280 at 20
°C
6.Charge:
battery
Battery charging amperage and
time
0.3 amps/10 hrs
Do not quick charge a battery.
Loosen the battery sealing caps.
To ensure maximum performance, always
charge a new battery before using it.
Do not use a high-rate battery charger.
They force a high-amperage current into
the battery quickly and can cause battery
overheating and battery plate damage.
If it is impossible to regulate the charging
current on the battery charger, be careful
not to overcharge the battery.
When charging a battery, be sure to remove
it from the scooter. (If charging has to be
done with the battery mounted on the
scooter, disconnect the negative battery
lead from the battery terminal.)
To reduce the chance of sparks, do not
plug in the battery charger until the battery
charger leads are connected to the battery.
Before removing the battery charger lead
clips from the battery terminals, be sure to
turn off the battery charger.
CAUTION:
CAUTION:
WARNING
CHECKING THE BATTERY
+
UPPER
LOWER
Page view 72