Yamaha 02R96-v2 Owner's Manual Page 27

  • Download
  • Add to my manuals
  • Print
  • Page
    / 350
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 26
Control Surface 27
02R96 Version 2—Owner’s Manual
DISPLAY ACCESS
A PHASE/INSERT button
This button is used to select the Input Channel Phase and Insert pages. See “Reversing the
Signal Phase” on page 73 and “Using Inserts” on page 115 for more information.
B DELAY button
This button is used to select the Delay pages. See “Delaying Channel Signals” on page 120
for more information.
DYNAMICS
A DYNAMICS DISPLAY button
This button is used to select the following pages: Gate Edit, Gate Library, Comp Edit, and
Comp Library. See “Gating Input Channels” on page 74 and “Compressing Channels on
page 116 for more information.
B GATE ON button
This button is used to turn the currently selected Input Channel’s Gate on and off. Its indi-
cator lights up when the Gate is on. See “Gating Input Channels” on page 74 for more infor-
mation.
C COMP ON button
This button is used to turn the currently selected channel’s Compressor on and off. Its indi-
cator lights up when the Compressor is on. See “Compressing Channels on page 116 for
more information.
D GATE/COMP button
This button is used to set the rotary controls for either Gate or Compressor operation.
When an Output Channel is selected, Compressor is selected automatically and cannot be
changed. See “Gating Input Channels on page 74 and “Compressing Channels” on
page 116 for more information.
E THRESHOLD, RANGE, ATTACK, DECAY, HOLD (THRESHOLD, RATIO, ATTACK,
RELEASE, GAIN) controls
When the GATE/COMP button is set to GATE, these controls set the Threshold, Range,
Attack, Decay, and Hold parameters of the currently selected Input Channel’s Gate. When
it’s set to COMP, they set the Threshold, Ratio, Attack, Release, and Gain parameters of the
currently selected channel’s Compressor. See “Gating Input Channels on page 74 and
“Compressing Channels” on page 116 for more information.
F GATE/COMP indicators
These indicators show whether the rotary controls are set to control a Gate or Compressor.
The GATE indicator lights up when they’re set to control a Gate; the COMP indicator, when
they’re set to control a Compressor. See “Gating Input Channels” on page 74 and “Com-
pressing Channels on page 116 for more information.
DISPLAY ACCESS
PHASE /
INSERT
DELAY
1 2
6
2
GATE ON COMP ON
GATE
COMP
RANGE
RATIO
ATTAC K
ATTAC KTHRESHOLD
THRESHOLD
DYNAMICS
DISPLAY
GATE / COMP
DECAY
RELEASE
HOLD
GAIN
1
3 4 5
Page view 26
1 2 ... 22 23 24 25 26 27 28 29 30 31 32 ... 349 350

Comments to this Manuals

No comments