2-4) Current word clock status query
devstatus lockstatus Queries the word clock lock status
Response
OK devstatus lockstatus "unlock" Unlock
OK devstatus lockstatus "lock" Lock
Example: Command: devstatus lockstatus
Response: OK devstatus lockstatus "lock"
Meaning: Query the word clock lock status.
Locked
3.3.2 Device run mode query
2-5) Emergency run mode change
devmode normal Sets the run mode to normal
emergency Sets the run mode to emergency
Response
OK devmode normal Normal run mode change complete
OK devmode emergency Emergency run mode change complete
Example: Command: devmode emergency
Response: OK devmode emergency
Meaning: Change to emergency mode.
Run mode was changed to emergency.
3.3.3. MTX external control protocol run mode setting
2-6) Result and change notification character encoding setting
scpmode encoding ascii ASCII encoding mode (default setting)
utf8 UTF-8 encoding mode
Response
OK scpmode encoding ascii ASCII encoding mode change complete
OK scpmode encoding utf8 UTF-8 encoding mode change complete
Example: Command: scpmode encoding utf8
Response: OK scpmode encoding utf8
Meaning: Change the result and change notification encoding code to UTF-8.
The encoding mode was changed to UTF-8.
2-7) Value notification mode setting
scpmode valuetype raw Raw value mode (default setting)
normalized Normalized value mode
Response
OK scpmode valuetype raw Raw value mode change complete
OK scpmode valuetype normalized Normalized value mode change complete
Example: Command: scpmode valuetype normalized
Response: OK scpmode valuetype normalized
Meaning: Change parameter change notifications to normalized value mode.
Parameter change notifications were changed to normalized value mode.
2-8) Normalization resolution setting
scpmode resolution (res) Resolution for normalized value notifications (default setting = 1000)
Details: (res) = Resolution for normalized values
Response
OK scpmode resolution xxxx The resolution for normalized value notifications
Details: xxxx = Specified resolution * Specified resolution should be more than 100.
Example: Command: scpmode resolution 128
Response: OK scpmode resolution 128
Meaning: Set the resolution of normalized values for setn commands to 128.
The resolution of normalized values for setn commands was set to 128.
2-9) Keepalive activation setting
scpmode keepalive (interval) Maximum interval for a client to send some kind of message, including heart beats (default setting = disabled)
Details: (interval) = Timeout value (msec) * Timeout value should be more than 1000.
* The actual timeout value will be increased by 1 second.
Response
OK scpmode keepalive xxxx The specified maximum interval
Details: xxxx = The specified timeout value (msec)
Example: Command: scpmode keepalive 2000
Response: OK scpmode keepalive 2000
Meaning: Set the timeout value to 2000 msec (2 seconds).
The timeout value was set to 2000 msec (2 seconds).
Option 1
Description
Option 2
Command
Description
Description
DescriptionOption 2
Option 1Command
Response string
Command Option 1
Response string
Description
Description
Option 1
Option 1
Description
Description
Response string Description
Response string
Option 2Command
Command
Option 2
Response string
Description
Command
Description
Option 1
Response string
Description
MTX3/MTX5-D/XMV Series/EXi8/EXo8 Remote Control Protocol Specifications V1.0.1
8
Page view 7
1 2 3 4 5 6 7 8 9 10 11 12 13 ... 44 45

Comments to this Manuals

No comments