Version 1.0.1 Release October 03, 2013This specification document applies to MTX3, MTX5-D, XMV, EXi8, and EXo8 V1.12 and later.MTX3, MTX5-D, XMV Ser
2-14) Normalized value parameter settingsetn MTX:mem_MemNo/UniqueId/ElmNo/Xpos/Ypos/PrmNo/IndexNo0 0 (value) Normalized value parameter settingDetails
3.3.7. Snapshot (preset) processing2-18) Snapshot (preset) current number query processingsscurrent Queries the current preset number (index)ResponseO
3-5) Serial number querydevinfo serialno Queries the serial numberResponseOK devinfo serialno "xxxx" Serial numberDetails: xxxx = Serial num
3.4.3. Event processing request3-10) Time synchronizationevent MTX:AbsoluteTime "yyyy/mm/dd hh:mm:ss" Changes the timeDetails: yyyy = Year (
3-15) Folder name list queryevent MTX:AudioPlayerGetDirNameList "dirindex=xxxx-xxxx" Folder name list: Multiple folder name query Details: x
3-19) Song playback status queryevent MTX:AudioPlayerGetStatus "" Song playback status queryResponseOK event MTX:AudioPlayerGetStatus "
3.5. Command Errors3.5.1. Command Error NotificationsError notification that indicates errors in commands.If an error is found when the command is sen
4. Command SequenceBelow are examples of how to process remote control.When viewed from the controller, the following major phases exist in order to p
Example when the controlled device starts earlier than the controller• If a logical session, as on an Ethernet network, needs to be established, the c
Meter data request/query sequenceThe controller requests meter data by specifying the meter data address and the minimum transmission interval.The met
0. Revision HistoryVersion Date Page # DescriptionV1.0.0 Sep. 1, 2013 - Initial version37Added note (*1) to XMV "InputSelect"44,45 Separated
5. Meter Value1.Level Meter, Hold MeterValue Data Value Data Value Data Value Data00 -126dBFS or less 20 -94dBFS 40 -62dBFS 60 -30dBFS01 -125dBFS 21 -
3.GATEDECAYValue Value Value Value0 43 86 1291 44 87 1302 45 88 1313 46 89 1324 47 90 1335 48 91 1346 49 92 1357 50 93 1368 51 94 1379 52 95 13810 53
4.COMPRESSORRATIO KNEE RELEASEValue Value Value Value ValueSame as GATE DECAY10 58 106 154 011 59 107 155 112 60 108 156 213 61 109 157 314 62 110 158
6.EFFECTTYPEValue0Reverb Hall1Reverb Stage12Karaoke Echo3Vocal EchoRevHallTime/RevStageTime KaraokeTime/VocalTimeValue Value Value00.300.46420210.413.
8.PRIORITY PROCESSOR1st/2nd PRIORITY DUCKER PRIORITY SOURCEANC SOURCEANC RATIOMTX3 MTX5-DValue Value Value Value0 0 31 51 1 32 62 2 33 73 3 34 84 4 35
11.YDIF PATCHMTX3 MTX5-DValue Value Value00NONE39THRU 111CH140THRU 222CH241THRU 333CH342THRU 444CH443THRU 555CH544THRU 666CH645THRU 777CH746THRU 888CH
7. Parameter ListMTX3/MTX5-DMTX3 MTX5-DMemNo(Memory Number)UniqueIdElmNo(Element Number)Xpos(X Position)Ypos(Y Position)PrmNo(Parameter Number)IndexNo
MTX3 MTX5-DMemNo(Memory Number)UniqueIdElmNo(Element Number)Xpos(X Position)Ypos(Y Position)PrmNo(Parameter Number)IndexNo(Index Number)unit RemarksMI
MTX3 MTX5-DMemNo(Memory Number)UniqueIdElmNo(Element Number)Xpos(X Position)Ypos(Y Position)PrmNo(Parameter Number)IndexNo(Index Number)unit RemarksMI
MTX3 MTX5-DMemNo(Memory Number)UniqueIdElmNo(Element Number)Xpos(X Position)Ypos(Y Position)PrmNo(Parameter Number)IndexNo(Index Number)unit RemarksMI
1. Setup1.1. Connection ProcedureConnection when using the NETWORK connector to perform remote control using this protocolMTX3MTX5-D* Also for XMV, EX
MTX3 MTX5-DMemNo(Memory Number)UniqueIdElmNo(Element Number)Xpos(X Position)Ypos(Y Position)PrmNo(Parameter Number)IndexNo(Index Number)unit RemarksMI
MTX3 MTX5-DMemNo(Memory Number)UniqueIdElmNo(Element Number)Xpos(X Position)Ypos(Y Position)PrmNo(Parameter Number)IndexNo(Index Number)unit RemarksMI
MTX3 MTX5-DMemNo(Memory Number)UniqueIdElmNo(Element Number)Xpos(X Position)Ypos(Y Position)PrmNo(Parameter Number)IndexNo(Index Number)unit RemarksMI
MTX3 MTX5-DMemNo(Memory Number)UniqueIdElmNo(Element Number)Xpos(X Position)Ypos(Y Position)PrmNo(Parameter Number)IndexNo(Index Number)unit RemarksMI
MTX3 MTX5-DMemNo(Memory Number)UniqueIdElmNo(Element Number)Xpos(X Position)Ypos(Y Position)PrmNo(Parameter Number)IndexNo(Index Number)unit RemarksMI
MTX3 MTX5-DMemNo(Memory Number)UniqueIdElmNo(Element Number)Xpos(X Position)Ypos(Y Position)PrmNo(Parameter Number)IndexNo(Index Number)unit RemarksMI
MTX3 MTX5-DMemNo(Memory Number)UniqueIdElmNo(Element Number)Xpos(X Position)Ypos(Y Position)PrmNo(Parameter Number)IndexNo(Index Number)unit RemarksMI
XMV Series4ch 8ch 4ch D 8ch DMemNo(Memory Number)UniqueIdElmNo(Element Number)Xpos(X Position)Ypos(Y Position)PrmNo(Parameter Number)IndexNo(Index Num
EXi8MemNo(Memory Number)UniqueIdElmNo(Element Number)Xpos(X Position)Ypos(Y Position)PrmNo(Parameter Number)IndexNo(Index Number)0 GAIN -6 66 dB1 +V48
EXo8MemNo(Memory Number)UniqueIdElmNo(Element Number)Xpos(X Position)Ypos(Y Position)PrmNo(Parameter Number)IndexNo(Index Number)0 Polarity Normal Inv
2. Command List1. Commands from a device sent to a remote controllerNo. Notification details1-1 Device status change notification Device run mode noti
8. Meter ListMTX3/MTX5-DMTX3 MTX5-DMemNo(Memory Number)UniqueIdoo20000 INPUT PORT INPUT(ANALOG) levelo20004 INPUT(YDIF)o20001o20002 INPUT(SLOT) levelo
MTX3 MTX5-DMemNo(Memory Number)UniqueIdTypeMeter Name RemarksAccess IDCategoryModelo40009 gro40010 gro40011 gro40012 gro40013 gro40014 gro40015 gro400
MTX3 MTX5-DMemNo(Memory Number)UniqueIdTypeMeter Name RemarksAccess IDCategoryModelo40023 gro20020 OUTPUT CHANNEL levelo20027 levelo20025 OUTPUT PORT
XMV Series4ch 8ch 4ch D 8ch DMemNo(Memory Number)UniqueIdoo- levelooleveloo- leveloolevelMeter NameSee 6. Parameter Value Details.CategoryModelRemarks
EXi8MemNo(Memory Number)UniqueId512 20000 - INPUT levelAccess IDTypeMeter 8 Channel(INPUT1-8)Meter NameSee Parameter Value Details.Category RemarksMT
EXo8MemNo(Memory Number)UniqueId512 20001 - OUTPUT levelAccess IDTypeMeter 8 Channel(OUTPUT1-8)Meter NameSee Parameter Value Details.Category Remarks
3. Command Specifications3.1. Basic Command SpecificationsBelow is the syntax of commands exchanged between a device and remote controller.<command
3.2.2. Parameter change notification1-5) Parameter change notification raw value Parameter change notification normalized valueNOTIFY set MTX:mem
1-12) Play, stop, and other transport operation notificationNOTIFY event MTX:AudioPlayerTransport "operation=stop" Stop"operation=play&
2-4) Current word clock status querydevstatus lockstatus Queries the word clock lock statusResponseOK devstatus lockstatus "unlock" UnlockOK
3.3.4. Parameter query2-10) Raw value parameter queryget MTX:mem_MemNo/UniqueId/ElmNo/Xpos/Ypos/PrmNo/IndexNo0 0 Raw value parameter query requestDeta