Yamaha MTX3 User Manual Page 3

  • Download
  • Add to my manuals
  • Print
  • Page
    / 45
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 2
1. Setup
1.1. Connection Procedure
Connection when using the NETWORK connector to perform remote control using this protocol
MTX3
MTX5-D
* Also for XMV, EXi8, and EXo8.
Connection when using the remote terminal to perform remote control using this protocol
MTX3
MTX5-D
* XMV, EXi8, and EXo8 do not have RS-232C connector
1.2. Configuring the Remote Controller
MTX3 and MTX5-D can be controlled from an external device through the Ethernet (NETWORK) terminal and remote (RS-232C) terminal.
XMV, EXi8, and EXo8 can be controlled from an external controller through the Ethernet (NETWORK) terminal.
The configuration on the remote controller side for each type of connection is shown below.
Ethernet (NETWORK connector) control
IP Address : S
p
ecif
y
the IP address of the device
y
ou want to control.
IP Port No. : 49280
Remote (RS-232C connector) control
RS232 port pin assignment
Bit Rate: The s
p
ecified bit rate.
Data: 8 bits
Parit
: none
Sto
p
bit: 1 bit
Flow Control : none
*Pin 4 and Pin 6 are connected internally.
*Pin 7 and Pin 8 are connected internally.
1.3. Device Configuration
1.3.1 MTX3 and MTX5-D
MTX3 and MTX5-D can be controlled via an external device through a NETWORK and RS-232C connector.
Two remote controllers can connect simultaneously via two available ports.
The first controller is fixed to using the NETWORK connector while the second controller can use the NETWORK or RS-232C connector.
The procedure to configure the second control port of MTX3 and MTX5-D is shown below, this is found in MTX Editor - System Menu- > Remote control.
(1) Select an MTX within the MTX system.
(2) Select NETWORK connector or RS-232C for Remote Control 2.
(3) Select 38400 or 115200 (if RS-232C is selected).
A
fter selecting all the parameters, click OK to complete the procedure.
* In the case of the MTX5-D NETWORK remote control connection, either network connector (Primary or Secondary) can be used when DANTE Daisy Chain mode is selected.
If using DANTE Redundant mode, only the Primary network connection and/or RS232 connection can be used for remote control.
1.3.2 XMV, EXi8, and EXo8
XMV, EXi8 and EXo8 can be controlled via an external device through a NETWORK connector.
Two remote controllers can connect simultaneously via two available ports.
As remote control of XMV, EXi8 and EXo8 is performed via the NETWORK connector only, there is no requirement to configure the port using MTX Editor.
When XMV
,
Exi8 and EXo8 are connected and controlled from MTX3 or MTX5-D
,
onl
y
one remote controller can be used
,
as one
p
ort is re
q
uired for s
y
stem control from MTX3 or MTX5-D.
-
In
Pin Name In/Out
DT
R
GND5
4 Out
-
7
8
9
Out3
2
1NC
RxD
TxD
In
Out
In
-
Name In/Out
6
Pin
DS
R
RTS
CTS
NC
(1)
(2)
(3)
Remote Controller
Ethernet
Ethernet
Network
Switch
Remote Controller
Ethernet
Ethernet
Network
Switch
RS-232C (Cross cable)
Remote Controller
RS-232C (Cross cable)
Remote Controller
MTX3/MTX5-D/XMV Series/EXi8/EXo8 Remote Control Protocol Specifications V1.0.1