3. Command Specifications
3.1. Basic Command Specifications
Below is the syntax of commands exchanged between a device and remote controller.
<command name> <option 1> <option 2> . . . <option n> <new line>
- Each command must end with LF (0x0A).
- At least one space is necessary between a command name and an option and between options.
- Commands must be expressed using ASCII characters. Other characters are not allowed.
- Option strings that express parameter values are shown below.
-Infinity "-INFINITY" -13801 0
-18dB "-18.00" -1800 810
-6.5dB "-6.50" -650 888
0dB "0.00" 0 932
10dB "10.00" 1000 1000
2kHz "2.00k" 2000 98
400Hz "400" 400 18
Pan L 63 "L63" -63 0
Pan Center "C" 0 500
Pan R 63 "R63" +63 1000
00
1 1000
00
1 1000
INVERTED "INVERTED" 1 1000
NORMAL "NORMAL" 0 0
* For other parameters, see section 6, "Parameter Value Details," provided later.
* Normalized value is a converted value when minimum value of
the parameter is as 0 and maximum value of the parameter is as 1000*1.
Example: -inf as minimum mapped 0, 10dB as maximum mapped 1000, 0dB mapped 932 for level parameter.
*1: This value is set by 2-8) Normalization resolution setting, default resolution is 1000.
3.2. Commands a Device Sends to a Remote Controller
3.2.1. Device status change notification
1-1) Device run mode notification
NOTIFY devstatus runmode "emergency" Emergency run mode
"update" Update mode
"normal" Normal run mode
Example: Notification: NOTIFY devstatus runmode "normal"
Meaning: The run mode was changed to normal mode.
1-2) Device error status notification
NOTIFY devstatus error "flt/xxxx" Alert fault information
"err/xxxx" Alert error information
"wrn/xxxx" Alert warning information
Details: "flt/xxxx" = "flt/ message// xnnn onf (sssss) ID-xxx 2012/12/31 23:59:59"
"err/xxxx" = "err/message// xnnn onf (sssss) ID- xxx 2012/12/31 23:59:59"
"wrn/xxxx" = "wrn/message// xnnn onf (sssss) ID-xxx 2012/12/31 23:59:59"
The first three characters indicate the alert type.
message = Alert message (The section from "/" to "//" after the alert type is the message data.) . . . up to 32 characters (ascii characters)
nnn = Alert number (panel display number) . . . 2 or 3 digit hexadecimal notation (The x at the front indicates hexadecimal notation.)
onf = Alert on/off . . . Persistent alerts turn on when an alert condition occurs and turn off when they are cleared.
Single-shot alerts turn on while an alert condition is true.
sssss = Identical alert count (a counter that indicates the number of identical alerts, normally set to 1) . . . Decimal notation
xxx = UNIT ID number . . . 3-digit hexadecimal
Date
Time
Example: Notification: NOTIFY devstatus error "err/DCP[0] communication error// x53 on (1) ID-001 2013/1/22 11:38:23"
Meaning: Error alert 53 occurred.
1-3) Current Fs (sampling frequency) setting notification
NOTIFY devstatus fs "unknown" Fs undefined
44.1kHz 44.1kHz
"48kHz" 48kHz
Example: Notification: NOTIFY devstatus fs "44.1kHz"
Meaning: Fs was changed to 44.1 kHz.
1-4) Current word clock status notification
NOTIFY devstatus lockstatus "unlock" Unlock
"lock" Lock
Example: Notification: NOTIFY devstatus lockstatus "lock"
Meaning: Word clock was locked.
DescriptionCommand Option 1
Command Description
Option 2 DescriptionCommand
Normalized valueDisplayed string
Command
Raw valueValue
Option 1 Description
ON "ON"
OFF "OFF"
Option 1
Option 2
Option 2
Option 2
Option 1
MTX3/MTX5-D/XMV Series/EXi8/EXo8 Remote Control Protocol Specifications V1.0.1
5
Page view 4
1 2 3 4 5 6 7 8 9 10 ... 44 45

Comments to this Manuals

No comments