37
SOUND LISTS & MIDI DATA
513 bytes or more shall not be received at one time. Thus,
if a dump request for 513 bytes or more is received, the data
must be divided into packets of 512 bytes or less, and the
packets transmitted with an appropriate time interval (120
msec or more).
3.2.1.1 XG System Data bulk dump
Refer to tables <1-1> and <1-2>.
3.2.1.2 Multi Effect1 Data bulk dump
Refer to tables <1-1> and <1-3>.
3.2.1.3 Part Data bulk dump
Refer to tables <1-1> and <1-4>.
3.2.2 P50-m Native bulk dump
11110000 F0 Exclusive status
01000011 43 YAMAHA ID
0000nnnn 0n Device No.
01010101 55 P50-m Model ID
0bbbbbbb bb Byte Count
0bbbbbbb bb Byte Count
0aaaaaaa aa Address High
0aaaaaaa aa Address Mid
0aaaaaaa aa Address Low
00000000 00 Data
|
|
0ccccccc cc Check-sum
11110111 F7 End of Exclusive
For the Address and Byte Count, refer to the accompanying
tables.
Check sum is the value which produces a lower 7 bits of
zero when the Start Address, Byte Count, and Check-sum
itself are added.
513 bytes or more shall not be received at one time. Thus,
if a dump request for 513 bytes or more is received, the data
must be divided into packets of 512 bytes or less, and the
packets transmitted with an appropriate time interval (120
msec or more).
3.2.2.1 P50-m System Data bulk dump
Refer to tables <2-1> and <2-2>.
4. Realtime Messages
4.1 Active Sensing
Once FE has been received, failure to receive subsequent
MIDI messages for an interval greater than approximately
300 msec will cause
the same processing to be performed as when SOUND OFF,
ALL NOTE OFF, and RESET ALL CONTROLLERS are
received, and then the instrument will return to the status of
not having received FE.
5. MIDI thru out
MIDI data that is received is re-transmitted (thru out) in the
following 2 modes.
5.1 When MIDI OUT=ot1
Data received at MIDI IN is re-transmitted (thru out) with-
out change.
5.2 When MIDI OUT=ot2
Data other than Key ON/OFF messages of the receive chan-
nel specified by MIDI CH will be re-transmitted (thru out).
However if the Receive Channel is set to ALL, or if the
voice number is 29 (Silence), all data will be re-transmitted
(thru out) without change.
When the setting is changed from ot1 to ot2, the change is
made simply, without performing any management of notes
which may be currently on. In some cases this can cause
problems; switching the setting to ot2 while notes are on
can cause stuck notes on a tone generator connected to
MIDI OUT.
Parameter Change
Address
(H) (M) (L)
Description
XG SYSTEM
00 00 00 System
00 00 7E XG System On
00 00 7F All Parameter Reset
EFFECT 1 02 01 00 Effect1(Reverb,Chorus)
PART 08 00 00 Part
< Table 1-1>
Parameter Base Address
Model ID = 4C [XG]