Chapter 5 Components
DME Designer Owner’s Manual
320
Title Bar
Displays the label. Label settings are made in the “Component Properties” dialog box. For
information about component labels see “Component” (page 235) in “Objects.”.
Back Button
This button appears in the child window of windows that have a parent-child relationship, and can
be clicked to return the parent window.
Status Bar
Component Name
Displays the component name.
Component ID
Displays the component ID.
Parameter ID
Displays the parameter ID for controls that are being operated.
Snap
Up to four component editor parameter sets can be recorded temporarily. You can switch between
parameter sets using buttons.
Parameter sets can be copied by dragging and dropping a button onto any other button. Copy can
also be carried out from the contextual menu that appears when a button is right-clicked.
See “Snap” on page 362
Library
Saves and recalls component editor parameter sets as files.
See “Library” on page 364.
NOTE
When controlling the DME64N/24N by connecting an RS-232C compatible controller to the [REMOTE] terminal, a
component ID is required for distinguishing the same components in the DME64N/24N. The component ID is included in
the signal that controls the component parameters. For details about control methods, contact your nearest Yamaha