Page view 61
PERIODIC MAINTENANCE AND MINOR REPAIR
6-16
6
2. Remove the oil filler bolt and drain
bolt to drain the oil from the final
gear case.
3. Install the final gear oil drain bolt,
and then tighten it to the specified
torque.
4. Add the recommended final gear
oil to the brim of the filler hole.
NOTE:
GL4 is a quality rating. Hypoid gear oils
rated GL5 or GL6 may also be used.
5. Install the oil filler bolt, and then
tighten it to the specified torque.
6. Check the final gear case for oil
leakage. If oil is leaking, check for
the cause.
EAU20070
Coolant
The coolant level should be checked
before each ride. In addition, the cool-
ant must be changed at the intervals
specified in the periodic maintenance
and lubrication chart.
EAU20211
To check the coolant level
1. Place the vehicle on a level sur-
face and hold it in an upright posi-
tion.
2. Remove panel A. (See page 6-8.)
NOTE:
The coolant level must be checked
on a cold engine since the level
varies with engine temperature.
Make sure that the vehicle is posi-
tioned straight up when checking
the coolant level. A slight tilt to the
side can result in a false reading.
3. Check the coolant level in the cool-
ant reservoir.
NOTE:
The coolant should be between the
minimum and maximum level marks.
Tightening torque:
Final gear oil drain bolt:
23 Nm (2.3 m·kgf, 17 ft·lbf)
Recommended final gear oil:
SAE80 API GL-4 Hypoid gear oil
Oil quantity:
0.20 L (0.21 US qt) (0.18 Imp.qt)
Tightening torque:
Final gear oil filler bolt:
23 Nm (2.3 m·kgf, 17 ft·lbf)