AE00812
APPLICATION RANGE
When using the generator, make sure the total load is within rated output of a generator.
Otherwise, generator damage may occur.
9 Do not overload. The total load of all electrical appliances must not exceed
the supply range of the generator. Overloading will damage the generator.
9 When supplying precision equipment, electronic controllers, PCs, electronic
computers, microcomputer-based equipment or battery chargers, keep the
generator a sufficient distance away to prevent electrical interference from
the engine. Also ensure that electrical noise from the engine does not inter-
fere with any other electrical devices located near the generator.
9 If the generator is to supply medical equipment, advice should first be
obtained from the manufacturer, a medical professional or hospital.
9 Some electrical appliances or general-purpose electric motors have high
starting currents, and cannot therefore be used, even if they lie within the
supply ranges given in the above table. Consult the equipment manufacturer
for further advice.
NOTICE
TIP
9 “–” means below.
9 Application wattage indicates when each device is
used by itself.
9 The simultaneous usage of AC and DC power is
possible but total wattage should not exceed the
rated output.
EX:
9 The overload indicator light comes on when total
wattage exceeds the application range. (See page
17 for more details.)
1 Overload indicator light
DC
AC
Power factor 1 0.80.95
0.40.75
(Efficiency 0.85)
2,500W 2,000W 850W
Rated voltage
12V
Rated current
10A
Generator rated output 2,500VA
Frequency Power factor
1.0 2,380W
AC
0.8 1,880W
120W
DC
(12V/10A)
EF2800i
760-021a
1
7VU-9-16-A 2/18/11 9:45 AM Page 15