– 24 –
Item Routine
Pre-
operation
check
Every
6 months
or 100 Hr
12 months
or 300 Hr
Fuel strainer Clean and replace if necessary. 1
Crankcase breather
Check breather hose for cracks or
hose
damage. 1
Replace if necessary.
Cylinder head
Decarbonize cylinder head.
More frequently if necessary.
Valve clearance Check and adjust when engine is cold.
Fittings / fasteners
• Check all fittings and fasteners.
• Correct if necessary.
The point where abnormality was recognized by use. 1
*1·····Initial replacement of the engine oil is after one month or 20 hours of operation.
*2·····The air filter element needs to be cleaned more frequently when using in unusually wet or dusty areas.
····· Since these items require special tools, data and technical skills, have a Yamaha dealer perform the ser-
vice.