Yamaha ES Owner's Manual Page 22

  • Download
  • Add to my manuals
  • Print
  • Page
    / 32
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 21
SB168-ES Owner’s Manual
22
Troubleshooting
The indicators will light and/or flash as shown until the cause is resolved.
The indicators will flash and/or light for 10 seconds.
Warning Messages
Indicators
AVS-ESMonitor
Error Status
Details Solution
Fan has Malfunctioned! The cooling fan has stopped
operating.
Check that nothing is caught in the fan. If
the problem cannot be easily resolved,
contact your Yamaha dealer.
Duplicate IP Address! A device with an IP address that
is the same as the SB168-ES
fixed IP address is connected to
the NETWORK connector.
Change the IP address of the device con-
nected to the NETWORK connector to an
IP address other than 192.168.0.2.
Illegal DIP Switch Setting! The device is operating with the
DIP switches set to initialization
or some other special mode.
To resume normal operation turn the
power OFF, set DIP switches 5–8 to their
“up” positions, then turn the power ON
again.
Information
Indicators
AVS-ESMonitor
Error Status
Details Solution
HA Remote Communication
Error! (Rx Buffer Full)
Too much data has been
received at the HA Remote input
port.
If any of these errors occur frequently, a
device malfunction may be the cause.
Contact your Yamaha dealer.
HA Remote Communication
Error! (Overrun)
An inappropriate signal has been
received at the HA Remote input
port.
HA Remote Communication
Error! (Framing)
An inappropriate signal has been
received at the HA Remote input
port.
HA Remote Communication
Error! (Tx Buffer Full)
Too much data has been trans-
mitted via the HA Remote output
port.
on flashon
flashonon
flashonflash
flash
flashflash
flashon
flashflash
Page view 21