Yamaha V150A User Manual Page 16

  • Download
  • Add to my manuals
  • Print
  • Page
    / 46
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 15
 TEST EXECUTION EASY LINK FUNCTION
Test is started => Current test pulse and all test parameters are displayed.
You can interrupt the test, move on to the next text or cancel the test at
any time.
Of course you can enter a comment for each step executed so that
EVERYTHING is documented afterwards. When using an external
measuring device for test monitoring, you define the steps manually
first, then the measuring device executes them automatically.
Fully automatic test routines can be created.
With the EASY LINK function, it’s quite easy connect test pulses and
power supply anomalies from the library.
ABSOLUTE CONTROL. TEST EXECUTION
AND TEST RESULTS ARE ALWAYS IN VIEW.
“IN A CLASS BY ITSELF: COMPOSE FULLY
AUTOMATIC TESTS
“IN A CLASS BY ITSELF: COMPOSE FULLY
iso.control
Software
Automated test runs are completely preprogrammed with the Easy Link.
Just click the desired tests and start them. Custom test routines can
be created easily with the link generator.
 TEST ROUTINES
Fully automatic test routines can be created with the link generator.
In the link file, test files are compiled into a fully automatic test routine.
The iso.control software takes charge of all of the measuring and test
devices.
You can concentrate fully on your DUT while iso.control handles
everything else.
 TEST DOCUMENTATION
iso.control registers test interruptions, recognizes DUT operational condi-
tions that have been set up previously (monitoring by an external measuring
device), and adds the respective comments to the relevant parameters
and test times. The pulse forms recorded by the oscilloscope can also be
integrated into the test report.
Afterwards, the test reports can also be entered into any desired Windows
program (Word, Excel, etc.), where you can add with the corporate logo
(corporate identity), or additional text or information before saving them.
Company
Street
City
Tel:
Fax:
Email:
http://
This certificate shall not be published or reproduced other than in full.
(QWHU\RXURZQDGGLWLRQDOWH[W
C:\ProgramData\EM TEST\iso.control\Report\testreport.rtf Page 1 of 2
Test Report iso.control
Report No.: Rep. 1
Date of test: July-25-2013, 16:06
Tester: Michael Meier
Customer: Customer EM TEST GmbH
Standard: ISO 7637-2 (2011-03)
Application: 24 V system
Ambient
Temperature:
22 °C
Humidity: 50 %
Pressure: 96 kPa
Note: Here are the Notes
T e s t R e s u l t
Result: Test passed !
(Date) (Sign)
7HVW5HSRUWLVRFRQWURO
This certificate shall not be published or reproduced other than in full.
(QWHU\RXURZQDGGLWLRQDOWH[W
C:\ProgramData\EM TEST\iso.control\Report\testreport.rtf Page 2 of 2
A c c e s s o r i e s
Test Equipment 1 V12122332
Test Equipment 2 V343443
Test Equipment 3 V4542355
Test Equipment 4 V3534556
Test Equipment 5 V545454
Test Equipment 6 V567676
Test Equipment 7 V098089
Test Equipment 8 V0707070
Test Equipment 9 V0789089
Test Equipment 10 V98563498
T e s t P r o c e d u r e
Pulse Name: ISO 7637-2 (2011-03) : 4.6.3 Pulse 3b
Test generator: UCS200N100 Software No.: 000000
Serial No.: 123
Va (Alternator): 27.0 V Current limit: 70 A
Software: iso.control Version: 5.2.4
T e s t S e t u p
Vs: +300 V
f1: 10 kHz
t4: 10 ms
t5: 90 ms
tr: 5 ns
td: 150 ns
Ri: 50 Ohm
Coupling: Battery
Test duration: 1 s
T e s t R e s u l t
Test duration: 00:00:02 h
Result: Test passed !
 