SLOT field
This field enables you to make various settings related to the MY slots on the rear panel of the
console.
4 Card name
Indicates the type of card installed in the slot. If nothing is installed, “----” will appear.
5 SRC buttons
The SRC (Sampling Rate Converter) function can be switched on or off for a slot in which
an MY card (MY8-AE96S) that features the SRC function is installed. If another type of
card is installed, or if no card is installed, no SRC button will appear.
6 FREQUENCY display
Indicates the sampling frequency of input signals if the installed card can detect the
substatus of input signals, such as an AES/EBU card. If another type of card is installed,
or if no card is installed, “----” will appear.
7 EMPHASIS STATUS display
Indicates the emphasis information of input signals if the installed card can detect the
substatus of input signals, such as an AES/EBU card. If another type of card is installed,
or if no card is installed, “----” will appear.
Using cascade connections
Using multiple QL series consoles, or a QL console and an external mixing console (such as
a Yamaha PM5D) in a cascade connection enables buses to be shared among the devices.
This can be convenient if you want to use an external mixer to increase the number of inputs.
This section explains cascade connections and operation, using an example in which two QL
units are connected in a cascade configuration.
About cascade connections
To cascade two QL series consoles, you must first install digital I/O cards in the appropriate
slots, and connect the output ports of the sending unit (the cascade slave) to the input ports
of the receiving unit (the cascade master).
The following illustration shows an example in which two eight-channel digital I/O cards for
each unit are installed in the cascade slave QL unit and in the cascade master QL unit. The
DIGITAL OUT jacks of the sending unit are connected to the DIGITAL IN jacks of the receiving
unit.
In this example, up to twenty four buses chosen from MIX bus 1–16, MATRIX bus 1–8,
STEREO bus (L/R), MONO (C) bus, and CUE bus (L/R) can be shared, and the mixed signals
transmitted from the cascade master QL unit. (If you use two 16-channel digital I/O cards, all
buses can be shared among the devices.) When the required settings are made for the
cascade slave and for the cascade master, the bus signals of the cascade slave will be sent
via the slot to the buses of the cascade master, and the combined signals of both buses will
be output from the cascade master. If the Cascade Link function is enabled, the specified
operations or parameter changes performed on either QL series console will be followed by
the other QL console.
You must specify bus assignments for each slot or channel on each QL unit. Separate
procedures are outlined for the cascade slave and the cascade master.
QL BQL A
DIGITAL
OUT
DIGITAL
IN
Audio signals of
A + B
Audio signals of
unit A
Digital I/O card
(Cascade slave) (Cascade master)