5 -4
5
Parameters
■ Pulse train mode parameters
PRM64 Input type
Input range Default value Unit
0 to 3 0 –
Switches the mode and selects the input type for pulse train mode.
Setting value Description
0
1
2
3
Normal mode
Phase A / phase B (pulse train mode)
Pulse train / code input (pulse train mode)
CW / CCW input (pulse train mode)
* For information on each input form, refer to "signal description" in "3-2 I/O specifi-
cations and wiring".
PRM65 Input pulse evaluation
Input range Default value Unit
1 to 4 4 –
Selects the multiplication factor when the pulse input type is "phase A / phase B".
Setting value Description
1
2
3
4
1× (multiplied by 1)
2× (multiplied by 2)
4× (multiplied by 4)
PRM66 Input pulse logic
Input range Default value Unit
0 to 1 0 –
Selects the command pulse logic.
Setting value Description
0
1
Positive logic
Negative logic
* For information on the positive and negative logic, refer to "signal description" in
"3-2 I/O specifications and wiring".
PRM67
PRM68
E-gear 1 (G1)
E-gear 2 (G2)
Input range Default value Unit
1 to 32767 1
–
Sets the movement distance (pulse rate) per 1 command pulse. Here,
• E-gear 1 is the numerator in the electronic gear ratio (=G1/G2), while E-gear 2 is the
denominator.
• Make sure the setting is within a range of 1/20
(G1/G2) 100.
* See "4-4 Electronic gear function" for information on how to set the electronic gear.
PRM69 INH input
Input range Default value Unit
0 to 1 1 –
Enables/disables the INH input.
Setting value Description
0
1
Enable
Disable
5-3 Parameter description