Yamaha SRCX User Manual Page 39

  • Download
  • Add to my manuals
  • Print
  • Page
    / 82
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 38
33
CHAPTER2 DeviceNet Unit
2-8-4 When emergency stop signal is input
Dedicated
command
BUSY
END
EMG
READY
5ms or less 1ms or less
Emergency stop
The READY output turns OFF. The BUSY output turns OFF during running of a
dedicated command. The END output is unchanged.
To resume robot operation, after canceling emergency stop and checking that the
READY output is ON, input the SERVO command.