60L3D1X
20
Power trim and tilt system
Trim sensor
Setting resistance
Ω
9–11
Resistance (P – B)
Ω
9–387.6
Fluid type ATF Dexron
II
Brushes
Standard length mm (in) 12.0 (0.47)
Wear limit mm (in) 4.0 (0.16)
Commutator
Standard diameter mm (in) 25.0 (0.98)
Item Unit
Model
F200AET FL200AET
Maintenance specifications