Yamaha EF4500iSE - Inverter Generator Owner's Manual Page 15

  • Download
  • Add to my manuals
  • Print
  • Page
    / 66
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 14
10
Overload indicator light (red)
The overload indicator light comes on when an over-
load of a connected electrical device is detected, the
inverter control unit overheats, or the AC output volt-
age rises. Then, the AC protector will trip, stopping
power generation in order to protect the generator and
any connected electric devices. The AC pilot light
(green) will go off and the overload indicator light (red)
will stay on, but the engine will not stop running.
1 Overload indicator light
When the overload indicator light comes on and power
generation stops, proceed as follows:
1. Turn off any connected electric devices and stop
the engine.
2. Reduce the total wattage of connected electric
devices within the rated output.
3. Check for blockages in the cooling air inlet and
around the control unit. If any blockages are
found, remove them.
4. After checking, restart the engine.
TIP
The overload indicator light may come on for a few
seconds at first when using electric devices that
require a large starting current, such as a compressor
or a submersible pump. However, this is not a mal-
function.
1
763-7XFc
AC pilot light (green)
The AC pilot light comes on when the engine starts
and produces power.
1 AC pilot light
7XF-28199-12_a 2011.3.21 16:04 Page 10
Page view 14
1 2 ... 10 11 12 13 14 15 16 17 18 19 20 ... 65 66

Comments to this Manuals

No comments