3. Editing Project Properties
• Overview
You can edit parameters such as the environment and processor selection, amplifier voltage, and text in the Project Properties
window. Click in the tool bar or select [Project Properties (P)] from the [File (F)] menu, open the Project Properties window,
and edit the contents of the Project, Calculation, System, and Others views. These parameters may be saved as a user default
setting by clicking the button. When you click the button, all parameters in every tab sheet within the Project
Properties window are saved as the default setting. In order to apply the saved setting, click icon. When you create a
new project, the software default setting is applied.
• Project
Enter the details of your project. Note that when exporting the results as a Project Report, the following characters are
automatically replaced with “_” (underscore) in order to prevent false representation in HTML format.
Characters: < > & “
• Calculation
Atmospheric Condition
Enter “Humidity” and “Temperature”. These parameters affect the speed of sound and the air absorption coefficient. The default
settings are 50% for humidity and 20°C for temperature. Check the “Air Absorption” checkbox to take attenuation of high
frequency components due air absorption into account in calculations.