R Remote Version 3 Users Guide 1
R Remote Version 3
Users Guide
Thank you for choosing a Yamaha product.
This users guide explains setup and use of "R Remote," a Windows/Mac application that lets you
make parameter settings for the Rio3224-D/Rio1608-D/Ri8-D/Ro8-D/RSio64-D/RMio64-D
(subsequently "R series") units.
This application lets you edit the parameters of up to twenty four R series units from a single
computer. Even if the R series unit is not connected, you can mount it virtually and edit its settings
beforehand.
Up to two computers in which R Remote is installed can be connected to a single device. This means,
for example, that the main operator could operate a console such as the CL while two assistants make
detailed adjustments at the other locations.
Page view 0
1 2 3 4 5 6 ... 33 34

Summary of Contents

Page 1 - User’s Guide

R Remote Version 3 User’s Guide 1 R Remote Version 3 User’s Guide Thank you for choosing a Yamaha product. This user’s guide explains setup a

Page 2

R Remote Version 3 User’s Guide 10 Specify the computer's IP address Specify the computer's IP address so that it can communicate with

Page 3 - Contents

R Remote Version 3 User’s Guide 11 5. Make the following settings according to the IP address setting you made in "Settings on the R seri

Page 4 - System Requirements

R Remote Version 3 User’s Guide 12 For Mac Make TCP/IP settings for the computer as follows. 1. Click [System Preferences]→[Network]. The “Netwo

Page 5 - ■ Setup

R Remote Version 3 User’s Guide 13 Operating R Remote Start R Remote. Windows 7 users: click [Start]→[All Programs]→[Yamaha R Remote]→[R Remot

Page 6 - Set on the R series units

R Remote Version 3 User’s Guide 14 Areas of the screen The R Remote screen is broadly divided into three areas: the Device Selection Area, the I

Page 7

R Remote Version 3 User’s Guide 15 Device Selection Area When you click a display switching button, the corresponding R series unit is shown in

Page 8

R Remote Version 3 User’s Guide 16 Main Area This area shows the state of the selected R series unit and allows basic parameter editing. The disp

Page 9 - Power-on the R series units

R Remote Version 3 User’s Guide 17 You can double-click a numeric value box and enter a value directly from the keyboard. The level meter located

Page 10 - 3. Click [Properties]

R Remote Version 3 User’s Guide 18 Edit window This appears if you double-click in the main area other than on a controller, or if you right-cli

Page 11 - 6. Click [OK]

R Remote Version 3 User’s Guide 19 ⑥ [A.GAIN] knob Specifies the analog gain for the HA of the device. The current setting is shown in the numer

Page 12

R Remote Version 3 User’s Guide 2 NOTICE ・ Yamaha Corporation owns exclusive copyrights for the R Remote, and the user’s guide. ・ It is prohi

Page 13 - ■ Operating R Remote

R Remote Version 3 User’s Guide 20 For Ro8-D The Ro8-D has no settings that can be operated, so only the [SYSTEM] indicator and [SYNC] indicator

Page 14 - Areas of the screen

R Remote Version 3 User’s Guide 21 For RSio64-D You can change the RSio64-D settings. ① CARD NAME This indicates the names of the cards instal

Page 15 - Information Display Area

R Remote Version 3 User’s Guide 22 Red (On) UNLOCK A valid clock is not being input from the card. If an external device is connected to the cor

Page 16 - Main Area

R Remote Version 3 User’s Guide 23 SLOT1 1/2 On when using the word clock for channels 1/2 of slot 1 for the RSio64-D. Flashes*1 if there is no

Page 17

R Remote Version 3 User’s Guide 24  PRESET button As a template for editing the patch, you can call by selecting from preset patterns 1-7. 

Page 18

R Remote Version 3 User’s Guide 25 For RMio64-D You can change the RSio64-D settings. ① MADI [SRC ON] indicator MADI [SRC ON] button Switches

Page 19

R Remote Version 3 User’s Guide 26 indicator is on and then select “4Fs”. When “2Fs” is selected, the unit automatically detects the frame frequ

Page 20

R Remote Version 3 User’s Guide 27 “Network Setup” dialog box This appears when you choose [File] menu -> [Network Setup]. Here you can sel

Page 21

R Remote Version 3 User’s Guide 28 “Device Information” dialog box This appears when you choose [File] menu -> [Device Information]. This lis

Page 22

R Remote Version 3 User’s Guide 29 “IP Address” dialog box This appears when you click the [Set IP Address] button in the "Device Informatio

Page 23 - input/output is used

R Remote Version 3 User’s Guide 3 Contents Using the PDF manual ...

Page 24

R Remote Version 3 User’s Guide 30 “Properties” dialog box This dialog box appears when you click the [Properties] button in the "Device In

Page 25

R Remote Version 3 User’s Guide 31 Uninstalling the software(Removing the application) Windows: Use “Control Panel” to uninstall the software.

Page 26

R Remote Version 3 User’s Guide 32 Troubleshooting Problem Possible cause Action R series unit is not connected. The R series unit’s power sw

Page 27 - “Network Setup” dialog box

R Remote Version 3 User’s Guide 33 The external device is not outputting a signal Output a signal from the source device and make sure that the

Page 28

R Remote Version 3 User’s Guide 34 Decimal/hexadecimal conversion table R Remote only uses values in the range of decimal 1 to 24. Decimal He

Page 29

R Remote Version 3 User’s Guide 4 Using the PDF manual ・You can move to the corresponding page by clicking on links in the table of contents o

Page 30 - “Properties” dialog box

R Remote Version 3 User’s Guide 5 Setup The setup workflow is shown below. Install the R Remote ↓ Set on the R series units ↓ Connect the com

Page 31

R Remote Version 3 User’s Guide 6 Set on the R series units For Rio3224-D / Rio1608-D / Ri8-D When using R Remote to operate a Rio3224-D / Rio16

Page 32 - ■ Troubleshooting

R Remote Version 3 User’s Guide 7 If the network consists only of Dante devices and R Remote, we recommend that you use the AUTO IP setting. If

Page 33

R Remote Version 3 User’s Guide 8 REDUNDANT (4 down) ・START UP MODE Settings Switch NORMAL (Start up normally with the settings of the previ

Page 34 - Published 07/2015

R Remote Version 3 User’s Guide 9 Connect the computer and R series units Use an Ethernet cable to connect the computer and the R series units.