Yamaha CD REWRITABLE DRIVE CRW8824S User Manual Page 4

  • Download
  • Add to my manuals
  • Print
  • Page
    / 15
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 3
list of the additional packages on the CD that are not installed automatically by the Update Pack Set. If the
Wizard detects previous versions of any of the Update Pack CD packages on your system, the updated
version on the CD appears in the Chosen Packages list on the right. Use the Remove button to move
packages that you don't want to install from the Chosen Packages list to the Available Packages list. Any
packages that remain in the Available Packages list will not be installed.
NOTE: Some packages on the CD may not be presented in the Package Selection List. This happens when the Upgrade Wizard does
not find a previous version of the package on your system. In order to install such a package, you need to first install the package from
the original UnixWare 7.1.3 media used to install the system (along with any prerequisite packages). See the online Getting Started
Guide for UnixWare 7.1.3 installation instructions.
Once you are finished selecting packages, click Next to continue.
11. A summary of your package selections and the space they require on your hard disk is displayed. Click
Next
to confirm your selections and continue. Click Previous to go back to the previous step and change the
Package Selection List.
12. After you confirm your package selections, the Upgrade Wizard installs the packages you selected. It
displays a progress bar as each package is installed. When the Wizard is done, click Finish to exit.
13. If you followed Step 1a, go to the next step.
Otherwise, if you followed Step 1b, unmount the CD image and delete the marry device:
# umount /install
# marry -d /dev/marry/var/spool/pkg/uw713up1CDimage.iso
14. Reboot your system to rebuild the kernel. From the Desktop, use the SCOadmin Shutdown Manager. From
the command line, enter the following:
# shutdown -i6 -g0 -y
15. When the system comes back up, you can log in and check the installation as shown in the section Checking
Update Pack 1 Installation.
If you later decide that you want to add additional packages from the Update Pack CD, see the section
Installing Additional Packages after the Update Pack Set.
Installing from Package Images
Separate images for the Update Set and all available packages on the CD (e.g., uw713up1.image, nd.image,
etc.).
These are in datastream format and must be installed using the pkgadd command. Follow this procedure to install
the images you download.
NOTE: You must install the uw713up1 set before installing any of the other packages available with Update Pack 1.
1. Download the set and package images from the SCO Update Service, and place them in /var/spool/pkg (or
any other directory that has enough free space to accommodate the images).
2. Enter the following to install the update set:
# pkgadd -d /var/spool/pkg/uw713up1.image all
3. Enter the following command for each additional package image:
# pkgadd -d /var/spool/pkg/imagename all
4. Reboot your system to rebuild the kernel. From the Desktop, use the SCOadmin Shutdown Manager. From
the command line, enter the following:
4 of 15
UnixWare 7.1.3 Update Pack 1 New Features and Notes
Page view 3
1 2 3 4 5 6 7 8 9 ... 14 15

Comments to this Manuals

No comments