INSP
ADJ
3-29
FUSE INSPECTION
1. Remove:
8 Battery box cover
Refer to “COVER AND PANEL” section.
2. Remove:
8 Fuse 1
3. Inspect:
8 Fuse 1
defectiveReplace
***************************************
Blown fuse procedure steps:
8 Turn off ignition and the circuit.
8 Install a new fuse of proper amperage.
8 Turn on switches to verify operation of elec-
trical device.
8 If fuse blows immediately again, check cir-
cuit in question.
***************************************
w
Never use a fuse with an amperage rating other
than that specified. Improvising or using a fuse
with the wrong amperage rat-ing may cause
extensive damage to the electrical system,
cause the lighting and ignition systems to mal-
function and could possibly cause a fire.
Description Amperage Quantity
Main 7A 1
4. Install:
8 Fuse
8 Battery box cover
4. Inspect:
8 Battery terminal
Dirty terminalClean with wire brush.
Poor connectionCorrect.
NOTE:
After cleaning terminals, apply lightly to the
terminals.
5. Install
8 Battery
8 Battery box cover