Yamaha CDX-E200 Service Manual Page 11

  • Download
  • Add to my manuals
  • Print
  • Page
    / 44
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 10
RX-E200
RX-E200
10
1630
115
AM GND FM
AM Adjustment (This should be done after FM adjustment.)
Connection Diagram (Measuring instruments)
1) Sensitivity verification
Reception
frequency
1080kHz
* (B-2)
Adjustment
point
Signal (ANT IN)
AM ANT
1080kHz
1kHz
Modulation off
AM ANT
60dBµ
Test point
AM ANT
Adjustment item
Verification of
sensitivity
Verification of auto
tuning
Step
1
2
Rating
S/N should be 20dB at frequency
of 1080kHz.
Check to ensure that the voltage at
the ANT terminal is 54dBµ or less.
Auto reception should be avail-
able when the tuning key is moved
UP and DOWN.
*:Execution of FACTORY PRESET (Refer to page 7.) will facilitate setting reception frequency for adjustment.
GND
AM loop antenna
AM ANT
TUNER
P. C. B.
AM SG
AM
dummy
antenna
ACVM
DIST. M
Oscilloscope
L
R
REC
OUT
Adjustment of discriminator balance
http://www.xiaoyu163.com
http://www.xiaoyu163.com
Page view 10
1 2 ... 6 7 8 9 10 11 12 13 14 15 16 ... 43 44

Comments to this Manuals

No comments