Yamaha V3 Owner's Manual Page 116

  • Download
  • Add to my manuals
  • Print
  • Page
    / 518
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 115
Chapter 3 Main Panel Window
DME Designer Owner’s Manual
116
[Time Adjustment]
GPI input can be used to adjust the DME internal clock as follows:
[Parameter], [Min], and [Max] are not available.
[Terminal] determines how the GPI input voltage will affect the specified parameter.
and specify continuous control of continuously-variable parameters from an external
fader, knob, or similar device.
and specify on/off control of 2-state parameters via an external switching device.
The internal clock time will be adjusted each time the voltage applied to GPI IN rises from below to
above the median voltage.*
The internal clock time will be adjusted each time the voltage applied to GPI IN drops from above to
below the median voltage.*
Same as .
Same as .
Internal clock time Time after adjustment
0~14 seconds Returned to 0 seconds
15~29 seconds Advanced to 30 seconds
30~44 seconds Returned to 30 seconds
45~59 seconds Advanced to 0 seconds
Max. voltage applied to GPI IN
Min. voltage applied to GPI IN
Median voltage
Trig ger
Max. voltage applied to GPI IN
Min. voltage applied to GPI IN
Median voltage
Trigger
Page view 115
1 2 ... 111 112 113 114 115 116 117 118 119 120 121 ... 517 518

Comments to this Manuals

No comments