SOUND CONTROLLER 6 adjusts the envelope decay time specified by the Voice. This
is a relative parameter, and specifies an increase or decrease centered at 64.
BRIGHTNESS adjusts the cutoff frequency specified by the Voice. This is a
relative parameter, and specifies an increase or decrease centered at 64.
Decreasing the value will make the sound more mellow. For some voices, the
effective range may be less than the range of the setting.
SOUND CONTROLLER 7 adjusts the LFO Frequency specified by the Voice. This is a
relative parameter, and specifies an increase or decrease centered at 64.
(3-2) CHANNEL MODE MESSAGES
STATUS 1011nnnn(BnH) n = 0 ~ 15 VOICE CHANNEL NUMBER
CONTROL NUMBER 0ccccccc c = CONTROL NUMBER
CONTROL VALUE 0vvvvvvv v = DATA VALUE
(3-2-1) ALL SOUND OFF (CONTROL NUMBER = 78H , DATA VALUE = 0)
Turns off the sound of all currently sounding notes on the corresponding
channel. The status of channel messages such as Note On and Hold On is also
turned off.
(3-2-2) RESET ALL CONTROLLERS (CONTROL NUMBER = 79H , DATA VALUE = 0)
Resets the values of the following controllers.
PITCH BEND CHANGE 0 (center)
MODULATION 0 (off)
AC1 CONTROLLER 0 (minimum)
EXPRESSION 127 (maximum)
SUSTAIN SWITCH 0 (off)
PORTAMENTO SWITCH 0 (off)
SOSTENUTO SWITCH 0 (off)
SOFT PEDAL 0 (off)
NRPN Un-set status. Internal data will not change.
RPN Un-set status. Internal data will not change.
PORTAMENT CONTROL reset
The following data will not change.
PROGRAM CHANGE, BANK SELECT MSB/LSB, VOLUME, PAN, HARMONIC CONTENT, RELEASE
TIME, ATTACK TIME, BRIGHTNESS, SOUND CONTROLLER 6,SOUND CONTROLLER 7, DRY SEND
LEVEL,EFFECT SEND LEVEL 1, EFFECT SEND LEVEL 3,EFFECT SEND LEVEL 4,PITCH BEND
SENSITIBITY, FINE TUNING, COURSE TUNING
(3-2-3) ALL NOTE OFF (CONTROL NUMBER = 7BH , DATA VALUE = 0)
Turns off all notes of the corresponding channel which are on. However if
Sustain or Sostenuto are on, the sound will continue until these are turned off.
(3-2-4) OMNI MODE OFF (CONTROL NUMBER = 7CH , DATA VALUE = 0)
Performs the same processing as when ALL NOTE OFF is received. Sets the VOICE
RECEIVE CHANNEL to OMNI OFF and CHANNEL = 1.
(3-2-5) OMNI MODE ON (CONTROL NUMBER = 7DH , DATA VALUE = 0)
Performs the same processing as when ALL NOTE OFF is received. Does not set OMNI
ON. Sets the VOICE RECEIVE CHANNEL to OMNI ON.
(3-2-6) MONO (CONTROL NUMBER = 7EH , DATA VALUE = 0)
Performs the same processing as when All SOUND OFF is received, and if the 3rd
byte (mono number) is in the range 0 - 16, sets the corresponding channel to
Mode 4 (m=1). If in the VOICE MODE, Mode 2 (m=1) is also possible, according to
the VOICE RECEIVE CHANNEL.
(3-2-7) POLY (CONTROL NUMBER = 7FH , DATA VALUE = 0)
Performs the same processing as when ALL SOUND OFF is received, and sets the
corresponding channel to Mode 3. When in the VOICE MODE, Mode 1 is also
possible, according to the VOICE RECEIVE CHANNEL.
(3-3) REGISTERED PARAMETER NUMBER
STATUS 1011nnnn(BnH) n = 0 - 15 VOICE CHANNEL NUMBER
LSB 01100100(64H)
RPN LSB 0ppppppp
p = RPN LSB (Refer to the table on the following page.)
MSB 01100101(65H)
RPN MSB 0qqqqqqq
q = RPN MSB (Refer to the table on the following page.)
DATA ENTRY MSB 00000110(06H)
DATA VALUE 0mmmmmmm m = Data Value
DATA ENTRY LSB 00100110(26H)
DATA VALUE 0lllllll l = Data Value
First transmit an RPN MSB and RPN LSB to specify the parameter that is to be
controlled, then use Data Entry to set the value of the specified parameter.
RPN D.ENTRY
LSB MSB MSB LSB PARAMETER NAME DATA RANGE
00H 00H mmH --- PITCH BEND SENSITIVITY 00H - 18H (0 - 24 semitones)
01H 00H mmH llH MASTER FINE TUNE
{mmH,llH} = {00H,00H} - {40H,00H} - {7FH,7FH}
(-8192*100/8192) - 0 - (+8192*100/8192)
02H 00H mmH --- MASTER COARSE TUNE
28H - 40H - 58H (-24 - 0 - +24 semitones)
7FH 7FH --- --- RPN RESET
Set to a condition in which the RPN number is unspecified.
Internal settings will not change.
(3-4) NON-REGISTERED PARAMETER NUMBER
STATUS 1011nnnn(BnH) n = 0 - 15 VOICE CHANNEL NUMBER
LSB 01100010(62H)
RPN LSB 0ppppppp
p = NRPN LSB (Refer to the table on the following page.)
MSB 01100011(63H)
RPN MSB 0qqqqqqq
q = NRPN MSB (Refer to the table on the following page.)
DATA ENTRY MSB 00000110(06H)
DATA VALUE 0mmmmmmm m = Data Value
First transmit an NRPN MSB and NRPN LSB to specify the parameter that is to be
controlled, then use Data Entry to set the value of the specified parameter.
NRPN D.ENTRY
MSB LSB MSB LSB PARAMETER NAME DATA RANGE
01H 08H mmH --- VIBRATO RATE 00H - 40H - 7FH (-64 - 0 - +63)
01H 09H mmH --- VIBRATO DEPTH 00H - 40H - 7FH (-64 - 0 - +63)
01H 0AH mmH --- VIBRATO DELAY 00H - 40H - 7FH (-64 - 0 - +63)
01H 20H mmH --- FILTER CUTOFF FREQUENCY 00H - 40H - 7FH (-64 - 0 - +63)
01H 21H mmH --- FILTER RESONANCE 00H - 40H - 7FH (-64 - 0 - +63)
01H 63H mmH --- EG ATTACK TIME 00H - 40H - 7FH (-64 - 0 - +63)
01H 64H mmH --- EG DECAY TIME 00H - 40H - 7FH (-64 - 0 - +63)
01H 66H mmH --- EG RELEASE TIME 00H - 40H - 7FH (-64 - 0 - +63)
(3-5) SYSTEM REAL TIME MESSAGES
(3-5-1) ACTIVE SENSING
STATUS 11111110 (FEH)
Transmitted at intervals of approximately 200 msec.
Not transmitted during disk read/write operations.
Once this message is received, SENSING will begin. If neither STATUS nor DATA
messages are received for an interval longer than approximately 350 msec, the
MIDI RECEIVE BUFFER will be cleared, and all sounding notes and SUSTAIN SWITCH
will be forced off. Also, data for each of the controls will be reset to
specific values.
(3-6) SYSTEM EXCLUSIVE MESSAGE
(3-6-1)UNIVERSAL NON REALTIME MESSAGE
(3-6-1-1)GENERAL MIDI MODE ON
F0H 7EH 7FH 09H 01H F7H
The following controller values will be reset.
VOLUME 100
PAN Center
PROGRAM CHANGE 1 (Grandpno)
BANK SELECT MSB 0
REVERB DEPTH 4
PITCH BEND CHANGE 0 (center)
MODULATION 0 (off)
EXPRESSION 127 (maximum)
SUSTAIN SWITCH 0 (off)
SOSTENUTO SWITCH 0 (off)
RPN Un-set status.
PORTAMENT CONTROL reset
MIDI MASTER VOLUME 127 (maximum)
PITCH BEND SENSITIBITY 02 (2 semitones)
FINE TUNING 0
COURSE TUNING 0
(3-6-1-2)IDENTITY REQUEST (Received only)
F0H 7EH 0nH 06H 01H F7H ("n" is the device number, but the RM1x
receives this in Omni.)
(3-6-1-3)IDENTITY REPLY (Transmitted only)
F0H 7EH 7FH 06H 02H 43H 00H 41H ddH ddH 00H 00H 00H 01H F7H
dd;Device Number Code RM1x = 1DH,03H
(3-6-2)UNIVERSAL REALTIME MESSAGE
(3-6-2-1) MIDI MASTER VOLUME
F0H 7FH 7FH 04H 01H llH mmH F7H
Modifies the MASTER VOLUME value.
The value of mm is used as the MIDI Master Volume (the ll value is
ignored).
(3-6-3)PARAMETER CHANGE
(3-6-3-1) MIDI MASTER TUNING
F0H 43H 1nH 27H 30H 00H 00H mmH llH ccH F7H
Modifies the MASTER TUNE value.
The values of mm and ll are used as the MIDI Master Tuning.(n and cc
values are ignored.)
T = M*200/256-100
Where T : actual tuning value (-99 - +99)
M: a one-byte value with MSB of "mm" bits 0-3, and LSB of
"ll" bits 0-3.
(3-6-3-2) XG SYSTEM ON
11110000 F0 Exclusive status
01000011 43 YAMAHA ID
0001nnnn 1n device Number
01001100 4C Model ID
0aaaaaaa 00 Address High
0aaaaaaa 00 Address Mid
0aaaaaaa 7E Address Low
00000000 00 Data
11110111 F7 End of Exclusive
When ON is received, controllers will be reset and all Multi Part and
Effect data of the attached table will be reset to the XG default
values.
(3-6-3-3) XG PARMETER CHANGE
11110000 F0 Exclusive status
01000011 43 YAMAHA ID
0001nnnn 1n device Number
01001100 4C Model ID
0aaaaaaa aaaaaaa Address High
0aaaaaaa aaaaaaa Address Mid
0aaaaaaa aaaaaaa Address Low
0ddddddd ddddddd Data
||
11110111 F7 End of Exclusive
For parameters with a Data Size of 2 or 4, the corresponding amount of
data will be transmitted.
For Addresses and Byte Counts, refer to the attached tables.
The following 3 types are received.
System Data
Multi Effect Data
Multi Part Data