MU50 MIDI Data Format
10
1. Channel messages
1.1 Key on / Key off
Reception note range =C-2~G8
Velocity range = 1~127 (Velocity is received only for Note Off)
Not received by a Part for which the Multi Part parameter Rcv NOTE MESSAGE =
OFF
Not received by a Rhythm Part for which Rcv NOTE OFF = OFF
Key On is not received by a Rhythm Part for which Rcv NOTE ON = OFF
1.2 Control change
Control Changes are not received by a Part for which the Multi Part parameter Rcv
CONTROL CHANGE = OFF
1.2.1 Bank Select
Cntrl# parameter Data Range
0 Bank Select MSB 0:Normal, 64:SFX, 126-127:Drum
32 Bank Select LSB 0...127
Bank Select processing is suspended until a Program Change is received.
When Sound Module Mode = C/M, all Bank Select messages are ignored.
1.2.2 Modulation
Cntrl# parameter Data Range
1 Modulation 0...127
When the Multi Part parameter Rcv MODULATION = OFF, that Part will not receive
Modulation messages.
1.2.3 Portamento Time
Cntrl# parameter Data Range
5 Portamento Time 0...127
When the parameter 1.2.9 Portamento = ON, this adjusts the speed of pitch change.
A setting of 0 is minimum portamento time, and 127 is longest portamento time.
1.2.4 Data Entry
Cntrl# parameter Data Range
6 Data Entry MSB 0...127
38 Data Entry LSB 0...127
Use this to set the value of the parameter specified by RPN and NRPN.
1.2.5 Main Volume
Cntrl# parameter Data Range
7 Main Volume 0...127
When the Multi Part parameter Rcv VOLUME = OFF, that Part will not receive
Volume messages.
1.2.6 Pan
Cntrl# parameter Data Range
10 Pan 0...127
0 is left, 127 is right.
When the Multi Part parameter Rcv PAN = OFF, that Part will not receive Pan
messages.
1.2.7 Expression
Cntrl# parameter Data Range
11 Expression 0...127
When the Multi Part parameter Rcv EXPRESSION = OFF, that Part will not receive
Expression messages.
1.2.8 Hold1
Cntrl# parameter Data Range
64 Hold1 0...127
(0-63:off, 64-127:on)
When the Multi Part parameter Rcv HOLD1 = OFF, that Part will not receive Hold1
messages.
1.2.9 Portamento
Cntrl# parameter Data Range
65 Portamento 0...127
(0-63:off, 64-127:on)
When the Multi Part parameter Rcv PORTAMENTO = OFF, that Part will not receive
Portamento messages.
1.2.10 Sostenuto
Cntrl# parameter Data Range
66 Sostenuto 0...127
(0-63:off, 64-127:on)
When the Multi Part parameter Rcv SOSTENUTO = OFF, that Part will not receive
Sostenuto messages.
1.2.11 Soft Pedal
Cntrl# parameter Data Range
67 Soft Pedal 0...127
(0-63:off, 64-127:on)
When the Multi Part parameter Rcv SOFT PEDAL= OFF, that Part will not receive Soft
Pedal messages.
1.2.12 Harmonic Content
Cntrl# parameter Data Range
71 Harmonic Content 0...127
(0:-64, 64:+0, 127:+63)
This message adjusts the resonance specified by the voice data. Since this is a relative
change parameter,
specify the increase or decrease relative to a center value of 64. Higher values will result
in a more characteristic sound.
Depending on the voice, the range of effect may be narrower than the range available
for setting.
1.2.13 Release Time
Cntrl# parameter Data Range
72 Release Time 0...127
(0:-64, 64:+0, 127:+63)
This message adjusts the envelope release time specified by the voice data. Since this is
a relative change parameter,
specify an increase or decrease relative to a center value of 64.
1.2.14 Attack Time
Cntrl# parameter Data Range
73 Attack Time 0...127
(0:-64, 64:+0, 127:+63)
This message adjusts the envelope attack time specified by the voice data. Since this is a
relative change parameter,
specify an increase or decrease relative to a central value of 64.
1.2.15 Brightness
Cntrl# parameter Data Range
74 Brightness 0...127
(0:-64, 64:+0, 127:+63)
This message adjusts the cutoff frequency specified by the voice data. Since this is a
relative change parameter,
specify an increase or decrease relative to a central value of 64. Lower values will result
in a softer sound.
For some voices, the range of effect may be narrower than the range available for
adjustment.
1.2.16 Portamento Control
Cntrl# parameter Data Range
84 Portamento Control 0...127
Portamento Control is transmitted specifying the Note On Key of currently-sounding
note.
Specify a Portamento Source Key number of 0~127. When a Portamento Control
message is received,
the currently sounding pitch will change with a Portamento Time of 0 to the key of the
next-received Note On on the same channel.
This message is received even if Rcv PORTAMENTO = OFF
1.2.17 Effect1 Depth ( Reverb Send Level )
Cntrl# parameter Data Range
91 Effect1 Depth 0...127
This message sets the send level for the reverb effect.
1.2.18 Effect3 Depth ( Chorus Send Level )
Cntrl# parameter Data Range
93 Effect3 Depth 0...127
This message sets the send level for the chorus effect.
Page view 10