AE00515
Generator wont produce power
Safety device (AC protector) to "Reset"····Press the AC protector to Set.
A ENGINE DOES NOT START
B
Turn the engine switch to ON, then turn
the engine switch to START. And check
if the starter motor cranks.
C Cranks D Does not crank
F
Turn the engine switch to START, and
check if the oil warning light comes on.
G Does not come on H Comes on
L
Turn the engine switch to START and
check the spark plug for spark strength.
(See WARNING).
w
9 To prevent FIRE HAZARDS be
sure fuel is not present in the
spark plug area.
9 To prevent FIRE HAZARDS be
sure to place the spark plug
as far way as possible from
the spark plug hole and car-
buretor area.
9 To prevent ELECTRIC SHOCK
do not hold spark plug lead
with hand while testing.
M Engine does not start. N Engine starts.
R
Check the following
9 Fuel cock clogging
9 Air cleaner element
clogging.
S Clogged
TOK
Clean or Replace; Consult a
Yamaha dealer.
U
V Consult a Yamaha dealer.