MIDI Data Format / MIDI-Datenformat / Format des données MIDI / Formato de datos MIDI
CVP-409/407/405/403/401 Data List
76
System Exclusive Messages (1)
[GM1] ... GM Required Parameter
[GM2] ... GM Level2 Required Parameter
* Not received when Receive System Exclusive Message Parameters is set to off.
* Not transmitted when Transmit System Exclusive Message Parameters is set to off.
System Exclusive Messages (Universal Real Time Messages)
[MIDI] [Song Creator]
MIDI Event Data Format Voice MIDI Reception MIDI Transmission PLAY REC
Regular/Drum/
Natural/Organ
Voice
Mic/
Vocal
Harmony
Song Right1/
Right2/
Left
Keyboard
Style Extra Right1/
Right2/
Left
Style Song Upper
Lower
PLAY REW From panel
operations
Master
Volume
[GM2]
F0 7F XN 04 01 SS TT F7
OX O
(Available for extra parts of a song)
OOOX
11110000
F0 = Exclusive status
01111111
7F = Universal Real Time
0xxxnnnn
XN = When N is received N = 0-F, whichever is received. X = ignored
00000100
04 = Sub-ID #1 = Device Control Message
00000001
01 = Sub-ID #2 = Master Volume
0sssssss
SS = Volume LSB
0ttttttt
TT = Volume MSB
11110111
F7 = End of Exclusive
Master Fine
Tuning
[GM2]
F0 7F XN 04 03 SS TT F7
OX O
(Available for extra parts of a song)
OOXX
11110000
F0 = Exclusive status
01111111
7F = Universal Real Time
0xxxnnnn
XN = When N is received N = 0-F, whichever is received. X = ignored
00000100
04 = Sub-ID #1 = Device Control Message
00000011
03 = Sub-ID #2 = Master Fine Tuning
0sssssss
SS = Fine Tuning LSB
0ttttttt
TT = Fine Tuning MSB
11110111
F7 = End of Exclusive
Master
Coarse
Tuning
[GM2]
F0 7F XN 04 04 00 TT F7
OX O
(Available for extra parts of a song)
OOXX
11110000
F0 = Exclusive status
01111111
7F = Universal Real Time
0xxxnnnn
XN = When N is received N = 0-F, whichever is received. X = ignored
00000100
04 = Sub-ID #1 = Device Control Message
00000100
04 = Sub-ID #2 = Master Coarse Tuning
00000000
00
0ttttttt
TT = Coarse Tuning MSB
11110111
F7 = End of Exclusive
Reverb
Parameter
[GM2]
F0 7F XN 04 05 01 01 01 01 01 PP VV ... F7
OO O O OOX
11000000
F0 = Exclusive status
01111111
7F = Universal Real Time
0xxxnnnn
XN = When N is received N = 0-F, whichever is received. X = ignored
00000100
04 = Sub-ID #1 = Device Control Message
00000101
05 = Sub-ID #2 = Global Parameter Control
00000001
01 = Slot path length = 1
00000001
01 = Parameter ID width = 1
00000001
01 = Value width = 1
00000001
01 = Slot path MSB = 1
00000001
01 = Slot path LSB = 1 (Reverb)
0ppppppp
PP = Parameter to be controlled.
0vvvvvvv
VV = Value for the Parameter.
: :
11110111
F7 = End of Exclusive
Parameter (pp) Value (vv) Display
-----------------------------------------------------------------------------
pp=0 Reverb Type 0...8 0: RoomS
1: RoomM
2: RoomL
3: HallM
4: HallL (default)
8: GM Plate
pp=1 Reverb Time 0...127 0...11.0s
Chorus
Parameter
[GM2]
F0 7F XN 04 05 01 01 01 01 02 PP VV ... F7 O O O O O O X
11110000
F0 = Exclusive status
01111111
7F = Universal Real Time
0xxxnnnn
XN = When N is received N = 0-F, whichever is received. X = ignored
00000100
04 = Sub-ID #1 = Device Control Message
00000101
05 = Sub-ID #2 = Global Parameter Control
00000001
01 = Slot path length = 1
00000001
01 = Parameter ID width = 1
00000001
01 = Value width = 1
00000001
01 = Slot path MSB = 1
00000010
02 = Slot path LSB = 2 (Chorus)
0ppppppp
PP = Parameter to be controlled.
0vvvvvvv
VV = Value for the Parameter
: :
11110111
F7 = End of Exclusive
Parameter (pp) Value (vv) Display
----------------------------------------------------------------------------
pp=0 Chorus Type 0...5 0: GM Chorus1
1: GM Chorus2
2: GM Chorus3
(default)
3: GM Chorus4
4: FB Chorus
5: GM Flanger
pp=1 Mod Rate 0...127 0...15.5Hz
pp=2 Mod Depth 0...127
pp=3 Feedback 0...127
pp=4 Send to Reverb 0...127
Channel
Pressure
(Aftertouch)
[GM2]
F0 7F XN 09 01 0M PP RR ... F7
OXO
X
X
XX
XXOXOX X
11110000
F0 = Exclusive status
01111111
7F = Universal Real Time
0xxxnnnn
XN = When N is received N = 0-F, whichever is received. X = ignored
00001001
09 = Sub-ID #1 = Controller Destination Setting
00000001
01 = Sub-ID #2 = Controller Type: 01 (Channel Pressure)
0000mmmm
0M= MIDI Channel (00-0F)
0ppppppp
PP = Controlled Parameter
0rrrrrrr
RR = Data
: :
11110111
F7 = End of Exclusive
Make sure to set both the controlled parameter and the range.
Parameters not set will be restored to their default values.
Control Parameter (pp) Data (RR) Description
Default Value
--------------------------------------------------------------------------------------------------------
pp=00 Pitch Control 28H~58H -24...0...+24semitones 40H
pp=01 Filter Cutoff Control 00H~FH -9600...0...+9450cents 40H
pp=02 Amplitude Control 00H~FH -100...0...+100% 40H
pp=03 LFO Pitch Depth 00H~FH 0...127 00H
pp=04 LFO Filter Depth 00H~FH 0...127 00H
pp=05 LFO Amplitude Depth 00H~FH 0...127 00H