Yamaha DSP-AX757SE Service Manual Page 16

  • Download
  • Add to my manuals
  • Print
  • Page
    / 48
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 15
42
RX-V757/DSP-AX757/DSP-AX757SE
RX-V657/HTR-5860
RX-V757/DSP-AX757/DSP-AX757SE
RX-V657/HTR-5860
IMP:8 PL:255
IMP SW/POWER LIMIT(インピーダンス/パワーリミッ
ターの検出)
IMP: このモデルには適用されません。
PL: パワーリミッター検出の値
IC451 92ピンの入力電圧値を5V/256を基準にして表
示します。IC451 92ピンの入力電圧値により、ポー
(3ピン)を制御します。
IMP SW/POWER LIMIT (impedance/power limiter
detection)
IMP: Not applied to these models.
PL: Power limiter detection value
The voltage value of pin No. 92 of IC451 is displayed,
using 5V/256 as standard.
The port (No. 3) output is controlled by using the
input voltage value of pin No. 92 of IC451.
DC/PS (protection detection)
DC: DC detect protection value
Normal value: 1 to 13 (Reference: 5V = 100%)
PS: Power supply voltageprotection value
Normal value: 36 to 49 (Reference: 5V = 100%)
When the value is outside of the normal range, the pro-
tection function works to turn off the power.
DC/PS(プロテクションの検出)
DC: DC検出プロテクションの値
正常値 1 ∼13(基準電圧 5V = 100%)
PS: 電源電圧プロテクションの値
正常値 36 ∼49(基準電圧 5V = 100%)
正常値を外れるとプロテクションが働き、電源オフ
れます。
10. AD DATA CHECK
キースキャン、異常検出プロテクション)ポート電圧のA/D
値などを表示します。
A/D変換値をサブメニューで%表示します。
オーディオ信号処理は実行前の状態を維持します。
K0/K1 のメニューにすると、全キーの値を検出するため
キー操作はできなくなりますが、本体のVOLUME を回すこ
とにより、次のサブメニューに進めることができます。こ
のとき 2 クリック以上回すと、ボリューム値が変化するの
で注意してください。
※図中の数値は参考例です。
10. AD DATA CHECK
With this sub-menu used, the key scanning, A/D value of the
voltage at the abnormality detect (protection) port, etc. are
displayed. The A/D conversion value is displayed in %.
The state before audio signal processing is kept.
When K0/K1 menu is selected, keys become nonoperable
due to detection of the values of all keys.
However, it is possible to advance to the next sub-menu by
turning the VOLUME of the main unit. When using this func-
tion, note that turning the VOLUME more than 2 clicks will
cause the volume value to change.
* The numeric value in the diagram is for reference.
DC:007 PS:043
THM:107
THM (temperature detection)
When the value is outside of the normal range, the
protection function works to turn off the power.
500% display of the voltage based on the tempera-
ture detected value. Reference voltage: 5V
For the correct value, refer to the table below.
THM(温度検出)
正常値を外れるとプロテクションが働き、電源オフさ
れます。
温度検出値で電圧の500%表示、基準電圧は5V
正常値は下表参照。
Destination U, C, T, K, B, G, E, J R, L
Normal Value 9 to 177 9 to 167
仕向け U, C, T, K, A, B, G, E, J R, L
正常値 9 ∼ 177 9 ∼ 167