Yamaha CRW8824IX Series Technical Information Page 101

  • Download
  • Add to my manuals
  • Print
  • Page
    / 128
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 100
Chapter 4 93
Power Management-Related Symptoms
Symptom / Error Action in Sequence
The system will not enter hibernation Keyboard (if control is from the keyboard)
Hard disk drive
Main Board
The system doesn't enter hibernation mode and
four short beeps every minute.
Press Fn+
m
and see if the computer enters hibernation mode.
Touchpad
Keyboard
Hard disk connection board
Hard disk drive
Main Board
The system doesn’t enter standby mode after
closing the LCD
LCD cover switch
Main Board
The system doesn't resume from hibernation
mode.
Hard disk connection board
Hard disk drive
Main Board
The system doesn't resume from standby mode
after opening the LCD.
LCD cover switch
Main Board
Battery fuel gauge in Windows doesn’t go higher
than 90%.
Remove battery pack and let it cool for 2 hours.
Refresh battery (continue use battery until power off, then charge
battery).
Battery pack
Main Board
Peripheral-Related Symptoms
Symptom / Error Action in Sequence
System configuration does not match the
installed devices.
Enter BIOS Setup Utility to execute “Load Default Settings”, then
reboot system.
Reconnect hard disk/CD-ROM/diskette drives.
External display does not work correctly.
Press Fn+
n
, LCD/CRT/Both display switching
Main Board
USB does not work correctly Main Board
Print problems. Ensure the “Parallel Port” in the “Onboard Devices Configuration” of
BIOS Setup Utility is set to Enabled.
Onboard Devices Configuration
Run printer self-test.
Printer driver
Printer cable
Printer
Main Board
Serial or parallel port device problems. Ensure the “Serial Port” in the Devices Configuration” of BIOS Setup
Utility is set to Enabled.
Device driver
Device cable
Device
Main Board
Page view 100
1 2 ... 96 97 98 99 100 101 102 103 104 105 106 ... 127 128

Comments to this Manuals