MIDI Data Table
TOTAL SIZE = 94 5E (HEX)
Address Size
Data Range
(HEX)
Parameter Name Description
Default
(HEX)
Notes
30 40 00 1 00, 20 – 7E Performance Name 1 0, 32 – 126 (ASCII) Initialized
Perform
01 1 00, 20 – 7E Performance Name 2 0, 32 – 126 (ASCII)
02 1 00, 20 – 7E Performance Name 3 0, 32 – 126 (ASCII)
03 1 00, 20 – 7E Performance Name 4 0, 32 – 126 (ASCII)
04 1 00, 20 – 7E Performance Name 5 0, 32 – 126 (ASCII)
05 1 00, 20 – 7E Performance Name 6 0, 32 – 126 (ASCII)
06 1 00, 20 – 7E Performance Name 7 0, 32 – 126 (ASCII)
07 1 00, 20 – 7E Performance Name 8 0, 32 – 126 (ASCII)
08 1 00, 20 – 7E Performance Name 9 0, 32 – 126 (ASCII)
09 1 00, 20 – 7E Performance Name 10 0, 32 – 126 (ASCII)
0A 1 00, 20 – 7E Performance Name 11 0, 32 – 126 (ASCII)
0B 1 00, 20 – 7E Performance Name 12 0, 32 – 126 (ASCII)
0C 1 00, 20 – 7E Performance Name 13 0, 32 – 126 (ASCII)
0D 1 00, 20 – 7E Performance Name 14 0, 32 – 126 (ASCII)
0E 1 00, 20 – 7E Performance Name 15 0, 32 – 126 (ASCII)
0F 1 00, 20 – 7E Performance Name 16 0, 32 – 126 (ASCII)
10 1 00, 20 – 7E Performance Name 17 0, 32 – 126 (ASCII)
11 1 00, 20 – 7E Performance Name 18 0, 32 – 126 (ASCII)
12 1 00, 20 – 7E Performance Name 19 0, 32 – 126 (ASCII)
13 1 00, 20 – 7E Performance Name 20 0, 32 – 126 (ASCII)
14 1 reserved
15 1 reserved
16 1 reserved
17 1 reserved
18 1 reserved
19 1 reserved
1A 1 reserved
1B 1 reserved
1C 1 00 – 04 Knob Function Select 0=Tone, 1=EG/FX,
2=EQ, 3=ARP/MS,
4=Assign
04
1D 1 00 – 01 Slider Function Select Part, Element 00
1E 1 reserved
1F 1 01 – 7F Performance Pan L63 – C – R63 40
20 1 reserved
21 1 00 – 7F AEG Attack Time -64 – +63 40
22 1 00 – 7F AEG Decay Time -64 – +63 40
23 1 00 – 7F AEG Sustain Level -64 – +63 40
24 1 00 – 7F AEG Release Time -64 – +63 40
25 1 00 – 7F FEG Attack Time -64 – +63 40
26 1 00 – 7F FEG Decay Time -64 – +63 40
27 1 reserved
28 1 00 – 7F FEG Release Time -64 – +63 40
29 1 00 – 7F FEG Depth -64 – +63 40
2A 1 00 – 7F Cutoff Frequency -64 – +63 40
2B 1 00 – 7F Resonance -64 – +63 40
2C 2 00 – 02
00 – 7F
Tempo 5 – 300
1st bit6-0 bit13-7
2nd bit6-0 bit6-0
00 5A
2E 1 reserved
2F 1 reserved
30 1 reserved
31 1 reserved
32 1 reserved
33 1 reserved
34 1 reserved
35 1 reserved
36 1 reserved
37 1 reserved
38 1 00 – 7F Performance Volume 0 – 127 7F
39 1 00 – 7F Portamento Time -64 – +63 40
3A 1 00 – 01 Portamento Switch Off, On 01
3B 1 00 – 7F USB Monitor Volume 0..127 7F
3C 1 reserved
3D 1 00 – 01 Assignable Switch 1
Mode
Momentary, Latch 01
3E 1 00 – 01 Assignable Switch 2
Mode
Momentary, Latch 01
3F 1 00 – 01 Motion Seq Hold
Switch Mode
Momentary, Latch 01
40 1 reserved
41 1 reserved
42 1 reserved
43 1 00 – 5F Ribbon Controller
Control Number
Off,1 – 95 10
44 1 00 – 5F Breath Controller
Control Number
Off,1 – 95 02
45 1 00 – 605F Foot Controller 1
Control Number
Off, 1 – 95, Super Knob 0B
46 1 00 – 605F Foot Controller 2
Control Number
Off, 1 – 95, Super Knob 04
47 1 00 – 5F Assignable Switch 1
Control Number
Off, 1 – 95 56
48 1 00 – 5F Assignable Switch 2
Control Number
Off, 1 – 95 57
49 1 00 – 5F Motion Seq Hold
Switch Control Number
Off, 1 – 95 58
4A 1 00 – 5F Motion Seq Trigger
Switch Control Number
Off, 1 – 95 59
4B 1 00 – 5F Assignable Knob 1
Control Number
Off, 1 – 95 11
4C 1 00 – 5F Assignable Knob 2
Control Number
Off, 1 – 95 12
4D 1 00 – 5F Assignable Knob 3
Control Number
Off, 1 – 95 13
4E 1 00 – 5F Assignable Knob 4
Control Number
Off, 1 – 95 14
4F 1 00 – 5F Assignable Knob 5
Control Number
Off, 1 – 95 15
50 1 00 – 5F Assignable Knob 6
Control Number
Off, 1 – 95 16
51 1 00 – 5F Assignable Knob 7
Control Number
Off, 1 – 95 17
52 1 00 – 5F Assignable Knob 8
Control Number
Off, 1 – 95 18
53 1 00 – 7F Assignable Knob 1
Value
0 – 127 40
54 1 00 – 7F Assignable Knob 2
Value
0 – 127 40
55 1 00 – 7F Assignable Knob 3
Value
0 – 127 40
56 1 00 – 7F Assignable Knob 4
Value
0 – 127 40
57 1 00 – 7F Assignable Knob 5
Value
0 – 127 40
58 1 00 – 7F Assignable Knob 6
Value
0 – 127 40
59 1 00 – 7F Assignable Knob 7
Value
0 – 127 40
5A 1 00 – 7F Assignable Knob 8
Value
0 – 127 40
5B 2 00 – 01
00 – 7F
Swing Offset -120 – 0 – +120
1st bit6-0 bit13-7
2nd bit6-0 bit6-0
01 00
5D 1 00 – 09 Unit Multiply 50%, 66%, 75%, 100%,
133%, 150%, 200%,
266%, 300%, 400%
03
Address Size
Data
Range
(HEX)
Parameter Name Description Default (HEX) Notes
30 41 00 2 00 – 7F
00 – 7F
Reverb Type Refer to Effect
Parameter List
01 00
02 1 00 – 7F Reverb Preset Number 00
03 2 00 – 7F
00 – 7F
Reverb Parameter 1 MSB
Reverb Parameter 1 LSB
: Init value for Rev-X
Hall / Basic
05 2 00 – 7F
00 – 7F
Reverb Parameter 2 MSB
Reverb Parameter 2 LSB
: Init value for Rev-X
Hall / Basic
07 2 00 – 7F
00 – 7F
Reverb Parameter 3 MSB
Reverb Parameter 3 LSB
: Init value for Rev-X
Hall / Basic
09 2 00 – 7F
00 – 7F
Reverb Parameter 4 MSB
Reverb Parameter 4 LSB
: Init value for Rev-X
Hall / Basic
0B 2 00 – 7F
00 – 7F
Reverb Parameter 5 MSB
Reverb Parameter 5 LSB
: Init value for Rev-X
Hall / Basic
0D 2 00 – 7F
00 – 7F
Reverb Parameter 6 MSB
Reverb Parameter 6 LSB
: Init value for Rev-X
Hall / Basic
0F 2 00 – 7F
00 – 7F
Reverb Parameter 7 MSB
Reverb Parameter 7 LSB
: Init value for Rev-X
Hall / Basic
11 2 00 – 7F
00 – 7F
Reverb Parameter 8 MSB
Reverb Parameter 8 LSB
: Init value for Rev-X
Hall / Basic
13 2 00 – 7F
00 – 7F
Reverb Parameter 9 MSB
Reverb Parameter 9 LSB
: Init value for Rev-X
Hall / Basic
15 2 00 – 7F
00 – 7F
Reverb Parameter 10 MSB
Reverb Parameter 10 LSB
: Init value for Rev-X
Hall / Basic
17 2 00 – 7F
00 – 7F
Reverb Parameter 11 MSB
Reverb Parameter 11 LSB
: Init value for Rev-X
Hall / Basic
19 2 00 – 7F
00 – 7F
Reverb Parameter 12 MSB
Reverb Parameter 12 LSB
: Init value for Rev-X
Hall / Basic
1B 2 00 – 7F
00 – 7F
Reverb Parameter 13 MSB
Reverb Parameter 13 LSB
: Init value for Rev-X
Hall / Basic
1D 2 00 – 7F
00 – 7F
Reverb Parameter 14 MSB
Reverb Parameter 14 LSB
: Init value for Rev-X
Hall / Basic
1F 2 00 – 7F
00 – 7F
Reverb Parameter 15 MSB
Reverb Parameter 15 LSB
: Init value for Rev-X
Hall / Basic
21 2 00 – 7F
00 – 7F
Reverb Parameter 16 MSB
Reverb Parameter 16 LSB
: Init value for Rev-X
Hall / Basic
23 2 00 – 7F
00 – 7F
Reverb Parameter 17 MSB
Reverb Parameter 17 LSB
: Init value for Rev-X
Hall / Basic
25 2 00 – 7F
00 – 7F
Reverb Parameter 18 MSB
Reverb Parameter 18 LSB
: Init value for Rev-X
Hall / Basic
27 2 00 – 7F
00 – 7F
Reverb Parameter 19 MSB
Reverb Parameter 19 LSB
: Init value for Rev-X
Hall / Basic
29 2 00 – 7F
00 – 7F
Reverb Parameter 20 MSB
Reverb Parameter 20 LSB
: Init value for Rev-X
Hall / Basic
2B 2 00 – 7F
00 – 7F
Reverb Parameter 21 MSB
Reverb Parameter 21 LSB
: Init value for Rev-X
Hall / Basic
2D 2 00 – 7F
00 – 7F
Reverb Parameter 22 MSB
Reverb Parameter 22 LSB
: Init value for Rev-X
Hall / Basic
Address Size
Data Range
(HEX)
Parameter Name Description
Default
(HEX)
Notes
MIDI PARAMETER CHANGE TABLE