Page view 12
MDX-E100
MDX-E100
9. TEST-REC mode
Use a disc for confirmation of recording function. (It is used to check the REC function at the specified address.)
Step Setting method Remark Display
1
2
3
4
5
Load a disc.
Press the TITLE button (REMOCON) twice.
Press the SET/ENTER button (REMOCON).
Press the SET/ENTER button (REMOCON).
Press the DELETE/CANCEL button
(REMOCON).
AUTO pre-adjustment menu
TEST-REC menu
ADDRESS setting (The initial value of the address is displayed.)
Set the search output to H while searching and back to L when
continuous reproduction is started.
Continuous recording
TEST-REC menu
[ _ AUT _ YOBI _ ]
[ TEST _ REC _ _ ]
[ a0050 _ pw ZZ ]
[ a XXXX _ pw ZZ ]
[ TEST _ REC _ _ ]
Every time the TITLE button (REMOCON) is pressed in the address setting mode, the address changes in the order of 0050-> 03C0 ->
0700 -> 08A0 -> 0050 ->
Pressing the DISPLAY button (REMOCON) in the TEST-REC menu changes to the AUTO pre-adjustment menu.
10. INNER mode
Step Setting method Remark Display
1
2
3
4
Load a disc.
Press the CHARA button (REMOCON).
Press the SET/ENTER button (REMOCON).
Press the DELETE/CANCEL button
(REMOCON).
AUTO pre-adjustment menu
INNER menu
INNER switch position is measured.
(Both SUBQ address and C1 error are displayed.)
INNER menu
[ _ AUT _ YOBI _ ]
[ _ _ INNER _ _ _ ]
[ s XXXX c YYYY ]
[ _ _ INNER _ _ _ ]
Pressing the DISPLAY button (REMOCON) in the INNER menu changes to the AUTO pre-adjustment menu.
11. EJECT mode
Step Setting method Remark Display
1
2
3
4
5
6
7
EJECT status in the TEST mode
Press the INPUT button (REMOCON).
Press the INPUT button (REMOCON).
Press the INPUT button (REMOCON).
Press the TITLE edit button (REMOCON).
Press the CHARA button (REMOCON).
Press the DELETE/CANCEL button
(REMOCON).
EJECT menu (No disc is loaded.)
Maximum power output status
Recording power output status
Reproduction power output status
To TEMP setting of EEPROM setting
(Refer to TEMP setting of EEPROM.)
To CONTROL setting of EEPROM setting
(Refer to CONTROL setting of EEPROM.)
EJECT menu
[ _ _ EJECT _ _ _ ]
[ xpw _ _ _ _ _ _ _ ]
[ rpw _ _ _ _ _ _ _ ]
[ ppw _ _ _ _ _ _ _ ]
[ _ _ EJECT _ _ _ ]
Confirmation of pick-up laser power
Recording and reproduction can be checked by using the laser power meter. However, it should be used for checking only
because there is variation in its measurement.
When the measured value is excessively deviated from the reference value, replace the pick-up.
Reference value (measured at room temperature of 25 °C)
During reproduction (ppw) : 0.72 ± 0.1 mW
During recording (vpw) : 5.5 ± 0.5 mW
Note : Be very careful when using the laser power meter. The laser beam would cause damage to your eye if exposed to it
directly.