Yamaha 505 Service Manual Page 17

  • Download
  • Add to my manuals
  • Print
  • Page
    / 92
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 16
GX-505/GX-505VCD
GX-505/VCD
Preset group
A
B
C
D
E
P1 P2 P3 P4 P5 P6 P7 P8
CAUTION : When executing Test program No. 2 RAM CLEAR, be sure to write down the preset memory contents of the
tuner, using a table like the one shown below. Execution of RAM CLEAR will set the memory contents of the
tuner back to the factory preset state which means that all the memories preset by the user will be erased.
FACT0RY PRESET
NOTE 1) PRESET PAGE ............................................ A : FM B : AM C : FM D : AM E : FM
BAND
FM (MHz)
AM (kHz)
MARKETS
U, C, R, T (100k/10k)
A, B, G, L, R, T (50k/9k)
U, C, R, T (100k/10k)
A, B, G, L, R, T (50k/9k)
8
107.9
107.90
1440
1440
7
106.1
106.10
1350
1350
6
88.1
88.10
900
900
5
107.9
108.00
1710
1611
4
101.5
101.50
530
531
3
87.5
87.50
1400
1404
2
95.1
95.10
1080
1080
1
98.1
98.10
630
630
PRESET No.
16
Equalizer test mode (Test program No. 01)
When the equalizer test mode is set, GEQ - xxx is displayed. xxx represents the 3 band value of GEQ.
It is possible to set the GEQ value directly, using the buttons on the remote control unit.
Example : To obtain flat
GEQ - 6 6 6
Low tone Intermediate tone High tone
Displayed value 0 123456789ABC
Gain (dB) -12 -10 -8 -6 -4 -2 0 +2 +4 +6 +8 +10 +12
Operation Procedure
To set a value for each band
[ 0 ] to [ 9 ], [ A(TIME) ], [ B(PROG) ], [ C(R.TIME)]
To set all bands to Min (-12dB)
[ D(EDIT) ]
To set all bands to Max (+12dB)
[ E(+10) ]
To cancel this test mode, press the STANDBY/ON button. (The normal operating mode will be restored.)
TAPE TEST MODE
When the TAPE TEST MODE is set through the SYSTEM TEST MODE, Tape Test XXXX appears on the FL display.
(XXXX is the counter value.)
The operating condition of the deck section will be as follows.
When the reverse mode is set to endless, the number of playback repetition becomes unlimited.
(It is set to 8 times in the normal operating mode.)
When in the REC mode, AUX/MD is used automatically for the input source.